Digitalni repozitorij raziskovalnih organizacij Slovenije

Izpis gradiva
A+ | A- | Pomoč | SLO | ENG

Naslov:PET/CT and MR improve interobserver agreement in primary tumor determination for radiotherapy in esophageal squamous cell cancer
Avtorji:ID Šečerov Ermenc, Ajra (Avtor)
ID Peterlin, Primož (Avtor)
ID Velenik, Vaneja (Avtor)
ID Jeromen, Ana (Avtor)
ID But-Hadžić, Jasna (Avtor)
ID Anderluh, Franc (Avtor)
ID Šegedin, Barbara (Avtor)
Datoteke:URL URL - Izvorni URL, za dostop obiščite https://pmc.ncbi.nlm.nih.gov/articles/PMC11941085/
 
.pdf PDF - Predstavitvena datoteka, prenos (566,23 KB)
MD5: 7B39585C29DCF30B8606C6217DDFCA65
 
Jezik:Angleški jezik
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:Logo OI - Onkološki inštitut Ljubljana
Povzetek:The aim of the study was to evaluate interobserver variability in the determination of the primary tumor for radiotherapy treatment planning in esophageal squamous cell carcinoma (ESCC). Methods: Sixteen patients with locally advanced ESCC were included in the analysis. In all patients positron emission tomography with computed tomography (PETC/CT) and magnetic resonance (MR) scans for radiotherapy planning were performed. Five experienced radiation oncologists delineated the primary tumor based on CT alone, MR alone, PET/CT, CT with fused MR and PET/CT with fused MR. Mean tumor volumes were calculated for each patient and imaging modality. The generalized conformity index (CIgen) was calculated to assess agreement in tumor determination. Results: The mean tumor volumes and CIgen for CT alone, MR alone, PET/CT, CT with fused MR and PET/CT with fused MR were 33.1 cm3, 30.2 cm3, 38.1 cm3, 31.9 cm3, 36.2 cm3 and 0.59, 0.64, 0.66, 0.63, 0.71, respectively. CIgen was significantly higher using PET/CT with fused MR compared to CT (p < 0.001) and PET/CT (p = 0.002) and using PET/CT compared to CT (alone) (p = 0.003). Conclusions: Our study showed higher agreement in primary tumor determination in ESCC using PET/CT compared to CT alone. Higher agreement was also found using PET/CT with fused MR compared to CT alone and PET/CT.
Ključne besede:magnetic resonance, positron emission tomography, squamous cell carcinoma, primary tumor
Status publikacije:Objavljeno
Verzija publikacije:Objavljena publikacija
Poslano v recenzijo:07.02.2025
Datum sprejetja članka:07.03.2025
Datum objave:11.03.2025
Kraj izida:Basel
Založnik:MDPI, Basel, Switzerland
Leto izida:2025
Št. strani:str. 690-1-690-10
Številčenje:Vol. 15, no. 6
Izvor:Basel, Switzerland
PID:20.500.12556/DiRROS-24005 Novo okno
UDK:616-006
ISSN pri članku:2075-4418
DOI:10.3390/diagnostics15060690 Novo okno
COBISS.SI-ID:230835203 Novo okno
Opomba:Nasl. z nasl. zaslona; Opis vira z dne 31. 3. 2025;
Datum objave v DiRROS:26.11.2025
Število ogledov:116
Število prenosov:46
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
  
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del revije

Naslov:Diagnostics
Skrajšan naslov:Diagnostics
Založnik:MDPI AG
ISSN:2075-4418
COBISS.SI-ID:519963673 Novo okno

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:magnetna resonanca, pozitronsko-emisijska tomografija, ploščatocelični rak, primarni tumor


Nazaj