| Naslov: | PET/CT and MR improve interobserver agreement in primary tumor determination for radiotherapy in esophageal squamous cell cancer |
|---|
| Avtorji: | ID Šečerov Ermenc, Ajra (Avtor) ID Peterlin, Primož (Avtor) ID Velenik, Vaneja (Avtor) ID Jeromen, Ana (Avtor) ID But-Hadžić, Jasna (Avtor) ID Anderluh, Franc (Avtor) ID Šegedin, Barbara (Avtor) |
| Datoteke: | URL - Izvorni URL, za dostop obiščite https://pmc.ncbi.nlm.nih.gov/articles/PMC11941085/
PDF - Predstavitvena datoteka, prenos (566,23 KB) MD5: 7B39585C29DCF30B8606C6217DDFCA65
|
|---|
| Jezik: | Angleški jezik |
|---|
| Tipologija: | 1.01 - Izvirni znanstveni članek |
|---|
| Organizacija: | OI - Onkološki inštitut Ljubljana
|
|---|
| Povzetek: | The aim of the study was to evaluate interobserver variability in the determination of the primary tumor for radiotherapy treatment planning in esophageal squamous cell carcinoma (ESCC). Methods: Sixteen patients with locally advanced ESCC were included in the analysis. In all patients positron emission tomography with computed tomography (PETC/CT) and magnetic resonance (MR) scans for radiotherapy planning were performed. Five experienced radiation oncologists delineated the primary tumor based on CT alone, MR alone, PET/CT, CT with fused MR and PET/CT with fused MR. Mean tumor volumes were calculated for each patient and imaging modality. The generalized conformity index (CIgen) was calculated to assess agreement in tumor determination. Results: The mean tumor volumes and CIgen for CT alone, MR alone, PET/CT, CT with fused MR and PET/CT with fused MR were 33.1 cm3, 30.2 cm3, 38.1 cm3, 31.9 cm3, 36.2 cm3 and 0.59, 0.64, 0.66, 0.63, 0.71, respectively. CIgen was significantly higher using PET/CT with fused MR compared to CT (p < 0.001) and PET/CT (p = 0.002) and using PET/CT compared to CT (alone) (p = 0.003). Conclusions: Our study showed higher agreement in primary tumor determination in ESCC using PET/CT compared to CT alone. Higher agreement was also found using PET/CT with fused MR compared to CT alone and PET/CT. |
|---|
| Ključne besede: | magnetic resonance, positron emission tomography, squamous cell carcinoma, primary tumor |
|---|
| Status publikacije: | Objavljeno |
|---|
| Verzija publikacije: | Objavljena publikacija |
|---|
| Poslano v recenzijo: | 07.02.2025 |
|---|
| Datum sprejetja članka: | 07.03.2025 |
|---|
| Datum objave: | 11.03.2025 |
|---|
| Kraj izida: | Basel |
|---|
| Založnik: | MDPI, Basel, Switzerland |
|---|
| Leto izida: | 2025 |
|---|
| Št. strani: | str. 690-1-690-10 |
|---|
| Številčenje: | Vol. 15, no. 6 |
|---|
| Izvor: | Basel, Switzerland |
|---|
| PID: | 20.500.12556/DiRROS-24005  |
|---|
| UDK: | 616-006 |
|---|
| ISSN pri članku: | 2075-4418 |
|---|
| DOI: | 10.3390/diagnostics15060690  |
|---|
| COBISS.SI-ID: | 230835203  |
|---|
| Opomba: | Nasl. z nasl. zaslona;
Opis vira z dne 31. 3. 2025;
|
|---|
| Datum objave v DiRROS: | 26.11.2025 |
|---|
| Število ogledov: | 116 |
|---|
| Število prenosov: | 46 |
|---|
| Metapodatki: |  |
|---|
|
:
|
Kopiraj citat |
|---|
| | | | Objavi na: |  |
|---|
Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše
podrobnosti ali sproži prenos. |