Digitalni repozitorij raziskovalnih organizacij Slovenije

Iskanje po repozitoriju
A+ | A- | Pomoč | SLO | ENG

Iskalni niz: išči po
išči po
išči po
išči po

Možnosti:
  Ponastavi


Iskalni niz: "ključne besede" (stainless steel) .

11 - 17 / 17
Na začetekNa prejšnjo stran12Na naslednjo stranNa konec
11.
Tribocorrosive study of new and in vivo exposed nickel titanium and stainless steel orthodontic archwires
Tadeja Kosec, Petra Močnik, Uroš Mezeg, Andraž Legat, Maja Ovsenik, Monika Jenko, John T. Grant, Jasmina Primožič, 2020, izvirni znanstveni članek

Povzetek: The surface, corrosion and wear properties of new and in vivo exposed nickel titanium (NiTi) and stainless steel (SS) archwires used in orthodontic treatment were investigated. Electrochemical and tribo-electrochemical tests in artificial saliva were performed in order to define corrosion properties and to estimate wear rate of new and in vivo exposed NiTi and SS archwires. The surface chemical analysis of the passive film on the NiTi and SS archwires before and after tribocorrosion tests was performed by Auger Electron Spectroscopy (AES). In vivo exposed NiTi and SS archwires had better electrochemical properties than new archwires due to the protective nature of oral deposits. Total wear and coefficients of friction were higher among in vivo exposed archwires and higher in NiTi archwires in comparison to SS archwires. The estimated thickness of the TiO2 passive film on as-received NiTi is 8 nm, while the passive Cr2O3 film on as-received SS is just 1–2 nm. On in vivo exposed NiTi archwire, a 60–80 nm thick organic film/dental plaque was observed, and on SS, it was thinner, at about 60 nm. This research shows the importance of combining AES with electrochemical testing, to characterize tribocorrosive properties of NiTi and SS orthodontic archwires.
Ključne besede: archwires, NiTi, stainless steel, wear
Objavljeno v DiRROS: 24.08.2023; Ogledov: 265; Prenosov: 114
.pdf Celotno besedilo (2,18 MB)
Gradivo ima več datotek! Več...

12.
Pitting corrosion on highly alloyed stainless steels in dilute sulphuric acid containing sodium chloride
Elina Huttunen-Saarivirta, Elisa Isotahdon, Zaiqing Que, M. Lindgren, Ahmad Mardoukhi, Jean-Baptiste Jorcin, Petra Močnik, Tadeja Kosec, Yassine El Ouazari, Sukanya Hägg Mameng, Lena Wegrelius, 2023, izvirni znanstveni članek

Povzetek: Stainless steels are widely used in industrial assets and equipment. Despite their good corrosion resistance under a wide range of operating conditions, there is the possibility of pitting corrosion in the presence of chlorides. However, very few studies have identified the safe operating conditions for various high-alloyed stainless steel grades by comparing their pitting susceptibility. In this research, the susceptibility to pitting attack of five stainless steels with austenitic and duplex microstructures was examined in dilute sulphuric acid solution with varying amounts of NaCl at the temperatures of 50, 90 and 130◦C. Based on potentiodynamic polarization scans, none of the test materials underwent pitting corrosion at 50◦C, but differences in susceptibility to pitting attack were clear between the test materials and NaCl concentrations at the temperature of 90◦C, and further tem- perature increase facilitated uniform corrosion. 28-day immersion tests at 90◦ C confirmed the pitting suscepti- bility of duplex grades 1.4662 (PREN 33) and 1.4462 (PREN 35) in the presence of at least 2000 mg/L NaCl, but not the susceptibility of a corresponding austenitic grade 1.4539 (PREN 34). The grades 1.4547 (PREN 43) and 1.4410 (PREN 44) were not susceptible to pitting corrosion under any of the studied conditions. The results from materials microstructural and electrochemical characterization are presented and discussed in this paper.
Ključne besede: stainless steel, austenitic stainless steel, duplex stainless steel, pitting atttack
Objavljeno v DiRROS: 12.07.2023; Ogledov: 307; Prenosov: 383
.pdf Celotno besedilo (42,24 MB)
Gradivo ima več datotek! Več...

13.
Sensor development for corrosion monitoring of stainless steels in H2SO4 solutions
Miha Hren, Tadeja Kosec, Mari Lindgren, Elina Huttunen-Saarivirta, Andraž Legat, 2021, izvirni znanstveni članek

Povzetek: Equipment made of different stainless steels is often used in the hydrometallurgical processing industry. In this study, an electrical resistance sensor was developed for monitoring corrosion in acidic solutions at high temperature. Two types of stainless steel were used as the electrode materials, namely grade 316L stainless steel (EN 1.4404) and grade 2507 duplex stainless steel (EN 1.4410). The materials and sensors were exposed to a 10% H2SO4 solution containing 5000 mg/L of NaCl at various temperatures. Results from the sensors were verified using electrochemical techniques and postexposure examination. Results showed that the microstructure played an important role in the interpretation of corrosion rates, highlighting the importance of using an appropriate stainless steel for the production of sensors. Electrochemical tests and postexposure examination both showed that the grade 2507 had a significantly lower corrosion rate compared to the grade 316L. Under industrial‑process conditions, the results for the grade 2507 sensor were promising with respect to sensor durability and performance, despite the extremely harsh operating environment.
Ključne besede: stainless steel, hydrometallurgical industry, sulphuric acid, electrical resistance sensor, corrosion
Objavljeno v DiRROS: 05.07.2023; Ogledov: 326; Prenosov: 183
.pdf Celotno besedilo (5,12 MB)
Gradivo ima več datotek! Več...

14.
Comparison of cycling high temperature corrosion at 650°C in the presence of NaCl of various austenitic stainless steels
Mirjam Bajt Leban, Maja Vončina, Tadeja Kosec, Robert Tisu, Matevž Barborič, Jože Medved, 2023, izvirni znanstveni članek

Povzetek: The high temperature corrosion at 650°C in the presence of NaCl at atmospheric pressure of AISI 304L, AISI 309, AISI 310S, AISI 314 and AISI 321 austenitic stainless steel was studied. The specimens were cyclically heated in the furnace and immersed in a 3.5% aqueous NaCl solution after cooling for 15 min. After each cycle, the change in mass of the samples was measured. The corroded samples were analysed by SEM /EDX, and the corrosion products were analysed by XRD. The chloride ions react with the steel surface to form porous and poorly adherent oxides and metal chlorides. After the mass increase during the first exposure cycles, spalling of the oxides occurred. The high temperature austenitic stainless steels (AISI 309, AISI 310S, AISI 314) showed less mass loss than conventional austenitic steels (AISI 304L). Surprisingly, the stainless steel AISI 321 showed a similar low weight loss after the cyclic test as AISI 309, but a detailed analysis of the exposed surfaces after the test showed a similar corrosion attack as for AISI 304. After the cyclic test at high temperature in the presence of NaCl, a higher concentration of Cr and Ni definitely improves the corrosion resistance under the present conditions, but a certain addition of Si is even more obvious.
Ključne besede: austenitic stainless steel, high temperature corrosion, NaCl, exhaust systems, open access
Objavljeno v DiRROS: 31.05.2023; Ogledov: 276; Prenosov: 175
.pdf Celotno besedilo (1,53 MB)
Gradivo ima več datotek! Več...

15.
Effect of surface machining on the environmentally-assisted cracking of Alloy 182 and 316L stainless steel in light water reactor environments : results of the collaborative project MEACTOS
Mariia Zimina, Stefan Ritter, Bojan Zajec, Marc Vankeerberghen, Liberato Volpe, Anna Hojna, Rik-Wouter Bosch, Fabio Scenini, Zaiqing Que, Alberto Sáez-Maderuelo, P. Jill Meadows, Michael Grimm, Matthias Herbst, Andraž Legat, Agostino Maurotto, Radek Novotny, Karl-Heinz Seifert, 2023, izvirni znanstveni članek

Povzetek: The main objective of the EU-funded project mitigating environmentally-assisted cracking through optimisation of surface condition (MEACTOS) was to gain knowledge on the ability of different surface machining procedures to mitigate environmentally-assisted cracking (EAC) in typical light water reactor structural materials and environments. Surfaces of cold-worked (CW) type 316L austenitic stainless steel and nickel-based weld metal Alloy 182 flat tapered tensile specimens were machined using different processes. EAC initiation susceptibility of these specimens was evaluated using constant extension rate tensile (CERT) tests under simulated boiling water reactor (BWR) and pressurized water reactor (PWR) conditions and assessed using constant load experiments. More than a hundred tests were performed covering about 10 years of autoclave testing time. Only minor or no measurable improvements in EAC initiation susceptibility as a function of surface treatments (grinding or advanced machining) compared to the standard industrial face milling were demonstrated. In most cases, the stress thresholds for EAC initiation determined in constant load tests confirmed the trend obtained from CERT tests. This paper summarises the most important results and conclusions concerning the EAC initiation behaviour for the CW 316L and Alloy 182 under reducing PWR and oxidizing BWR conditions.
Ključne besede: crack initiation, environmentally-assisted cracking, Alloy 182, AISI 304 stainless steel, surface treatment, light water reactor, open access
Objavljeno v DiRROS: 30.05.2023; Ogledov: 330; Prenosov: 189
.pdf Celotno besedilo (16,31 MB)
Gradivo ima več datotek! Več...

16.
17.
Iskanje izvedeno v 0.22 sek.
Na vrh