Naslov:Real-world data on the minimed 780G advanced hybrid closed-loop system use during type 1 diabetes pregnancy : one centre observational study
Avtorji:ID Munda, Ana (Avtor)
ID Kovacic, Chiara (Avtor)
ID Pongrac Barlovič, Draženka (Avtor)
Datoteke:.pdf PDF - Predstavitvena datoteka, prenos (822,80 KB)
MD5: A0B837434E99FDA037C794FF7E59A763
 
URL URL - Izvorni URL, za dostop obiščite https://www.sciencedirect.com/science/article/pii/S1056872724001211
 
Jezik:Angleški jezik
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:Logo UKC LJ - Univerzitetni klinični center Ljubljana
Povzetek:Aim The efficacy of hybrid closed-loop systems (HCLs) in managing glycemic control in pregnant women with type 1 diabetes remains inadequately characterized. We evaluated the use of the Medtronic Minimed 780G HCLs. Methods: The retrospective observational study analyzed the glycemic and perinatal outcomes of pregnant women using the HCLs, followed at our tertiary centre. Independent t-tests were employed to compare data among trimesters based on pre-pregnancy HbA1c. The associations between glycemic parameters and perinatal outcomes were explored using Spearman rho. Results: Among the 21 women (age: 33.5 ± 4.2 years, diabetes duration: 21.2 ± 7.6 years, pre-pregnancy HbA1c 7.0 ± 1.1 % (52.9 ± 11.9 mmol/mol)) time in range (pTIR, 63–140 mg/dl; 3.5–7.8 mmol/l) increased progressively throughout pregnancy (trimesters: first: 64.0 ± 9.0 %; second:71.3 ± 11.8 %; third: 75.7 ± 8.1 %). Simultaneously, mean sensor glucose decreased (trimesters: first: 130 ± 10.4 mg/dl (7.2 ± 0.6 mmol/l); second: 120.9 ± 13.4 mg/dl (6.7 ± 0.7 mmol/l); third: 117.3 ± 9.1 mg/dl (6.5 ± 0.5 mmol/l)). Although a majority of women achieved the target pTIR until the third trimester, this did not consistently prevent the delivery of a largefor-gestational-age baby. Notably, one ketoacidosis event occurred, and there were no reported instances of severe hypoglycemia. Conclusion: Use of the Minimed 780G HCLs enabled the attainment of recommended pregnancy glycemic targets for most women with type 1 diabetes in a real-world setting.
Ključne besede:Type 1 diabetes, pregnancy continuous glucose monitoring, closed-loop insulin delivery
Status publikacije:Objavljeno
Verzija publikacije:Objavljena publikacija
Leto izida:2024
Št. strani:str. 1-7
Številčenje:Vol. 38, iss. 8, [article no.] 108795
PID:20.500.12556/DiRROS-30020 Novo okno
UDK:616.379
ISSN pri članku:1873-460X
DOI:10.1016/j.jdiacomp.2024.108795 Novo okno
COBISS.SI-ID:200991491 Novo okno
Opomba:Nasl. z nasl. zaslona; Opis vira z dne 8. 7. 2024;
Datum objave v DiRROS:11.06.2026
Število ogledov:127
Število prenosov:134
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
  
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del revije

Naslov:Journal of diabetes and its complications
Založnik:Elsevier Science
ISSN:1873-460X
COBISS.SI-ID:23137285 Novo okno

Gradivo je financirano iz projekta

Financer:Drugi - Drug financer ali več financerjev
Program financ.:Univerzitetni klinični center Ljubljana
Številka projekta:20220126
Naslov:Biokemijski in citokinski označevalci iz sline pri obravnavi žensk z nosečnostno sladkorno boleznijo

Licence

Licenca:CC BY-NC 4.0, Creative Commons Priznanje avtorstva-Nekomercialno 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by-nc/4.0/deed.sl
Opis:Licenca Creative Commons, ki prepoveduje komercialno uporabo, vendar uporabniki ne rabijo upravljati materialnih avtorskih pravic na izpeljanih delih z enako licenco.

Nazaj