| Naslov: | OMERACT GCA phantom project : validation of a 3D-printed ultrasound training phantom for diagnosis of giant cell arteritis |
|---|
| Avtorji: | ID Schremmer, Tobias (Avtor) ID Dejaco, Christian (Avtor) ID Recker, Florian (Avtor) ID Aschwanden, Markus J. (Avtor) ID Boumans, Dennis (Avtor) ID Bruyn, George A. W . (Avtor) ID Chrysidis, Stavros (Avtor) ID Daikeler, Thomas (Avtor) ID Dalsgaard Nielsen, Berit (Avtor) ID De Miguel, Eugenio (Avtor) ID Hočevar, Alojzija (Avtor), et al. |
| Datoteke: | PDF - Predstavitvena datoteka, prenos (1,08 MB) MD5: C21AD30029E8B7CC7B415437E8B414DB
URL - Izvorni URL, za dostop obiščite https://rmdopen.bmj.com/content/11/1/e005316
|
|---|
| Jezik: | Angleški jezik |
|---|
| Tipologija: | 1.01 - Izvirni znanstveni članek |
|---|
| Organizacija: | UKC LJ - Univerzitetni klinični center Ljubljana
|
|---|
| Povzetek: | Objective: Ultrasonography is crucial for diagnosing giant cell arteritis (GCA); however, training opportunities are rare. This study tested the reliability of ultrasonography findings and measurements of the intima-media thickness (IMT) among ultrasonography experts by using phantoms of the axillary (AA) and temporal arteries (TA) created with high-resolution 3D printing. Methods: Twenty-eight participants from 12 European countries received eight sets of phantoms of the AA and the superficial TA (including common, frontal and parietal branches), which were examined in a blinded fashion according to a predefined protocol and evaluated based on Outcome Measures in Rheumatology (OMERACT) GCA ultrasound definitions. Due to difficulties with the delineation of the intima-media complex, the parietal branch of the phantoms was modified, and a second round was conducted. The IMT was measured, and phantoms were classified as normal or vasculitic. Results: In both rounds, the phantoms were correctly classified as normal/abnormal in >81% of cases yielding a Fleiss' kappa of 0.80 (95% CI 0.78 to 0.81) in round 1 and 0.74 (95% CI 0.72 to 0.75) in round 2. IMT measurements revealed an intraclass correlation coefficient (ICC 1.1) of 0.98 (95% CI 0.98 to 0.99) in both rounds. Intrarater reliability was good with a median Cohens Kappa of 0.83 and median ICC of 0.78. Conclusion: The study demonstrated high reliability among ultrasound experts in applying the OMERACT ultrasound definitions for GCA and in measuring the IMT using a 3D-printed phantom of the AA and TA. This phantom could assist clinicians in training to assess the large arteries of patients with suspected or established GCA. |
|---|
| Ključne besede: | giant cell arteritis, ultrasonography, vasculitis |
|---|
| Status publikacije: | Objavljeno |
|---|
| Verzija publikacije: | Objavljena publikacija |
|---|
| Leto izida: | 2025 |
|---|
| Št. strani: | str. 1-9 |
|---|
| Številčenje: | Vol. 11, iss. 1, [article no.] e005316 |
|---|
| PID: | 20.500.12556/DiRROS-29620  |
|---|
| UDK: | 616-002 |
|---|
| ISSN pri članku: | 2056-5933 |
|---|
| DOI: | 10.1136/rmdopen-2024-005316  |
|---|
| COBISS.SI-ID: | 277578243  |
|---|
| Opomba: |
Nasl. z nasl. zaslona;
Opis vira z dne 8. 5. 2026;
|
|---|
| Datum objave v DiRROS: | 01.06.2026 |
|---|
| Število ogledov: | 21 |
|---|
| Število prenosov: | 12 |
|---|
| Metapodatki: |  |
|---|
|
:
|
Kopiraj citat |
|---|
| | | | Objavi na: |  |
|---|
Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše
podrobnosti ali sproži prenos. |