| Naslov: | Er:YAG laser biofilm removal from zero-gap periodontal/peri-implant model system mimicking clinical attachment loss |
|---|
| Avtorji: | ID Volk, Marko (Avtor) ID Šavli, Dominik (Avtor) ID Molan, Katja (Avtor) ID Terlep, Saša (Avtor) ID Levičnik Hoefferle, Špela (Avtor) ID Trost, Mojca (Avtor) ID Gašpirc, Boris (Avtor) ID Lukač, Matjaž (Avtor) ID Jezeršek, Matija (Avtor) ID Stopar, David (Avtor) |
| Datoteke: | PDF - Predstavitvena datoteka, prenos (2,81 MB) MD5: EFCAE34F0EE60C8E842159D277B7CCE8
URL - Izvorni URL, za dostop obiščite https://www.spiedigitallibrary.org/journals/journal-of-biomedical-optics/volume-30/issue-02/025002/Er-YAG-laser-biofilm-removal-from-zero-gap-periodontal-peri/10.1117/1.JBO.30.2.025002.full
|
|---|
| Jezik: | Angleški jezik |
|---|
| Tipologija: | 1.01 - Izvirni znanstveni članek |
|---|
| Organizacija: | UKC LJ - Univerzitetni klinični center Ljubljana
|
|---|
| Povzetek: | Significance: Here, we present a photoacoustic method to remove biofilms from periodontal and peri-implant-constrained geometries. Aim: We aim to remove biofilms from narrow periodontal and peri-implant model systems with the application of Er:YAG ultrashort laser pulses. Approach: Construction of zero-gap model system from PDMS and titanium, growth of biofilms on titanium surfaces, and removal of biofilms with Er:YAG USP, 20 mJ, 15 Hz, and 10 s were performed. Results: The results suggest that geometry, the vertical position of the laser fiber tip, and the evolution of the primary cavitation bubble significantly affect cleaning effectiveness. Cleaning was higher in the wedge part of the model system. In the zero-gap part of the model system, biofilm cleaning effectiveness was highest at the position of the laser fiber tip and decreased above and below the fiber tip. The dimension of the space in which the cavitation bubble develops determines the size and dynamics of the expanded cavitation bubble and consequently the biofilm cleaning effectiveness. Conclusions: The obtained results suggest a very good biofilm removal effectiveness in difficult-to-reach narrow geometries mimicking clinical attachment loss in the periodontal/peri-implant pocket. |
|---|
| Ključne besede: | Er:YAG laser, photoacoustic removal, biofilm, attachment loss, in vitro model |
|---|
| Status publikacije: | Objavljeno |
|---|
| Verzija publikacije: | Objavljena publikacija |
|---|
| Leto izida: | 2025 |
|---|
| Št. strani: | str. 025002-1-025002-11 |
|---|
| Številčenje: | Vol. 30, issue 2 |
|---|
| PID: | 20.500.12556/DiRROS-28975  |
|---|
| UDK: | 579.61:544.537 |
|---|
| ISSN pri članku: | 1083-3668 |
|---|
| DOI: | 10.1117/1.JBO.30.2.025002  |
|---|
| COBISS.SI-ID: | 228534787  |
|---|
| Opomba: |
|
|---|
| Datum objave v DiRROS: | 15.04.2026 |
|---|
| Število ogledov: | 116 |
|---|
| Število prenosov: | 68 |
|---|
| Metapodatki: |  |
|---|
|
:
|
Kopiraj citat |
|---|
| | | | Objavi na: |  |
|---|
Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše
podrobnosti ali sproži prenos. |