Naslov:Two-year outcomes of tissue-level and bone-level two-piece zirconia implants : a case series
Avtorji:ID Žarković Gjurin, Sonja (Avtor)
ID Povšič, Katja (Avtor)
ID Kobe, Tom (Avtor)
ID Žužek, Borut (Avtor)
ID Gašperšič, Rok (Avtor)
ID Oblak, Čedomir (Avtor)
Datoteke:.pdf PDF - Predstavitvena datoteka, prenos (1,42 MB)
MD5: D42988EF7AF523CA902FED5D2E543E5C
 
URL URL - Izvorni URL, za dostop obiščite https://www.mdpi.com/2673-6373/6/1/1
 
Jezik:Angleški jezik
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:Logo UKC LJ - Univerzitetni klinični center Ljubljana
Povzetek:Background/objectives: Zirconia dental implants are increasingly recognised as an alternative to titanium implants due to their biocompatibility and aesthetics. Initially developed as one-piece systems, zirconia implants have evolved into two-piece designs with different platform levels; however, comparative data on their primary and secondary stability– particularly as assessed by resonance frequency analysis (RFA)—and marginal bone dynamics remain limited. This case series aimed to evaluate the implant stability and marginal bone changes of two-piece zirconia implants with bone-level (BL) and tissue-level (TL) platforms in patients missing maxillary premolars. Methods: Thirteen zirconia implants (n = 13; 7 BL, 6 TL; Z5-TL/Z5-BL, Z-Systems, Switzerland) were placed in 11 patients with healed ridges. The implant stability quotient (ISQ) was measured immediately after insertion and before prosthetic loading. Lithium disilicate crowns were cemented after four months, and follow-ups were conducted for an average of 35 months (SD = 12). Results: Initial ISQ values ranged from 73 to 79, increasing to 76–84 at 3–4 months, indicating high implant stability for both BL and TL implants. The extent of marginal bone loss (MBL) after two years was greater around BL implants (mean 0.46 mm) compared to TL implants (mean 0.2 mm), although probing depths and bleeding on probing remained minimal in both groups, with only one TL implant showing gingival recession. Conclusions: Over a short observation period, two-piece zirconia implants with tissue-level platforms appeared to demonstrate superior marginal tissue stability. Further, larger-scale controlled studies are required to confirm these preliminary observations.
Ključne besede:zirconia implants, ceramic, two-piece, bone-level, tissue-level, implant stability, ISQ
Status publikacije:Objavljeno
Verzija publikacije:Objavljena publikacija
Leto izida:2026
Št. strani:str. 1-13
Številčenje:Vol. 6, no. 1
PID:20.500.12556/DiRROS-28822 Novo okno
UDK:616.31
ISSN pri članku:2673-6373
DOI:10.3390/oral6010001 Novo okno
COBISS.SI-ID:264750083 Novo okno
Opomba:Nasl. z nasl. zaslona; Opis vira z dne 15. 1. 2026;
Datum objave v DiRROS:08.04.2026
Število ogledov:267
Število prenosov:217
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
  
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del revije

Naslov:Oral
Skrajšan naslov:Oral
ISSN:2673-6373
COBISS.SI-ID:80648451 Novo okno

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:cirkonijevi vsadki, keramika, dvodelni, na ravni kosti, na ravni tkiva, stabilnost vsadka