Naslov:Measurement noise attenuation in modified Smith predictor and automatic offset controllers for integrator plus dead-time system
Avtorji:ID Huba, Mikuláš (Avtor)
ID Bisták, Pavol (Avtor)
ID Vrančić, Damir, Institut "Jožef Stefan" (Avtor)
Datoteke:URL URL - Izvorni URL, za dostop obiščite https://www.nature.com/articles/s41598-026-39732-9
 
.pdf PDF - Predstavitvena datoteka, prenos (8,49 MB)
MD5: 544ABC38E85639C23AB84E12A6F6F2EB
Opis: The programs and datasets generated and analyzed during the current study are available in the Zenodo repository, https://www.doi.org/10.5281/zenodo.17364578.
 
Jezik:Angleški jezik
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:Logo IJS - Institut Jožef Stefan
Povzetek:The paper compares the recently modified Åström-Smith predictor (ASP) developed for IPDT models with an automatic offset controller (AOC). While an excellent performance can be achieved with ASP in idealized conditions, unacceptable transients with extraordinary high excessive controller effort and a steady-state control error result in the presence of measurement noise. AOC combines a possibly higher-order (HO) stabilizing controller (SC) with compensation of disturbances using a full disturbance observer (DOB). Nominal full DOB includes both the model dead-time and inversion of the integral mode of the model. By increasing the number of output derivatives used in the SC of the AOC, together with increasing the order of the low-pass filter used both in the SC and the DOB, it is possible to significantly increase the speed and robustness of responses in time-delayed processes, together with decreasing the measurement noise impact. The AOC based on the ultralocal IPDT model can be used to replace the higher-order PID in an universal controller for a wide class of processes with dominant first-order dynamics. Significant improvements in measurement noise attenuation can be demonstrated also in application of equivalent low-pass filters to the ASP. But even after such a modification of the noise attenuation, the filtered ASP can exhibit permanent control error or even instability at higher noise amplitudes. Hence, although even the ASP can be used as a universal controller for processes with dominant first-order dynamics, the benefit of its use should always be verified depending on the amplitude of the measurement noise. From this point of view, the use of AOC is simpler and more reliable. Despite the need for appropriate selection of the degree of derivatives used in SC and the tuning of the low-pass filters used. The conclusions of the article are illustrated by simulation experiments of unstable process control and real-time thermal process control.
Ključne besede:automatic reset, automatic offset, disturbance observer, higher-order derivatives, contrained control
Status publikacije:Objavljeno
Verzija publikacije:Objavljena publikacija
Poslano v recenzijo:03.10.2025
Datum sprejetja članka:06.02.2026
Datum objave:11.02.2026
Založnik:Nature Publishing Group
Leto izida:2026
Št. strani:str. 1-22
Številčenje:Vol. 16 article number 8335
Izvor:Združeno kraljestvo
PID:20.500.12556/DiRROS-28379 Novo okno
UDK:681.5
ISSN pri članku:2045-2322
DOI:10.1038/s41598-026-39732-9 Novo okno
COBISS.SI-ID:271760387 Novo okno
Avtorske pravice:© The Author(s) 2026
Opomba:Nasl. z nasl. zaslona; Opis vira z dne 16. 3. 2026;
Datum objave v DiRROS:16.03.2026
Število ogledov:42
Število prenosov:14
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
  
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del revije

Naslov:Scientific reports
Skrajšan naslov:Sci. rep.
Založnik:Nature Publishing Group
ISSN:2045-2322
COBISS.SI-ID:18727432 Novo okno

Gradivo je financirano iz projekta

Financer:ARIS - Javna agencija za znanstvenoraziskovalno in inovacijsko dejavnost Republike Slovenije
Številka projekta:P2-0001-2022
Naslov:Sistemi in vodenje

Financer:EC - European Commission
Številka projekta:101007175
Naslov:REliable Advanced Diagnostics and Control Tools for increased lifetime of solid oxide cell Technology
Akronim:REACTT

Financer:VEGA - Scientific Grant Agency of the Ministry of Education, Science, Research and Sport of the Slovak Republic and Slovak Academy of Sciences
Številka projekta:1/0821/25

Financer:Slovak Research and Development Agency
Številka projekta:APVV-24-0390

Licence

Licenca:CC BY-NC-ND 4.0, Creative Commons Priznanje avtorstva-Nekomercialno-Brez predelav 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by-nc-nd/4.0/deed.sl
Opis:Najbolj omejujoča licenca Creative Commons. Uporabniki lahko prenesejo in delijo delo v nekomercialne namene in ga ne smejo uporabiti za nobene druge namene.
Začetek licenciranja:11.02.2026
Vezano na:VoR

Nazaj