| Naslov: | The selective detection of individual respiratory droplets in air |
|---|
| Avtorji: | ID Malok, Matjaž, Institut "Jožef Stefan" (Avtor) ID Kavšek, Darko, Institut "Jožef Stefan" (Avtor) ID Remškar, Maja, Institut "Jožef Stefan" (Avtor) |
| Datoteke: | URL - Izvorni URL, za dostop obiščite https://pubs.acs.org/doi/10.1021/acssensors.5c02057
PDF - Predstavitvena datoteka, prenos (3,33 MB) MD5: A55BEE912838ABE102670AAC6E14F3D7 Opis: The data that support the findings of this study are available within the article, its Supporting Information file, and in Zenodo, https://doi.org/10.5281/zenodo.15489441.
|
|---|
| Jezik: | Angleški jezik |
|---|
| Tipologija: | 1.01 - Izvirni znanstveni članek |
|---|
| Organizacija: | IJS - Institut Jožef Stefan
|
|---|
| Povzetek: | Preventing the spread of airborne diseases in crowded indoor spaces is a global challenge. Infected individuals release virus-laden respiratory droplets (RDs) that can remain suspended in air and infectious for hours. Current monitoring methods cannot distinguish these droplets from airborne particulate matter (PM) in a real time. Here, we present a capacitive sensor that selectively detects and counts the individual droplets in indoor spaces, regardless the presence of PM. The device exploits the dielectric constant (ε) of water (78.2) to differentiate the droplets from solid PM particles (ε < 15). In a nonventilated conference-room study, RDs concentrations (40–330 RDs/L) were found to be correlated with human occupancy, but not with PM2.5 levels. The developed technology enables a real-time monitoring of number concentration of RDs, which represent a potential health risk when they carry viral or bacterial infections. The detected increase in RD concentration can serve as a trigger for data-driven ventilation and infection-prevention measures, providing an effective tool for mitigating the spread of respiratory diseases in hospitals, schools and other public spaces. |
|---|
| Ključne besede: | respiratory droplets, capacitive sensing, indor air monitoring, infection control |
|---|
| Status publikacije: | Objavljeno |
|---|
| Verzija publikacije: | Objavljena publikacija |
|---|
| Poslano v recenzijo: | 12.06.2025 |
|---|
| Datum sprejetja članka: | 10.12.2025 |
|---|
| Datum objave: | 16.12.2025 |
|---|
| Založnik: | American Chemical Society |
|---|
| Leto izida: | 2025 |
|---|
| Št. strani: | str. A-H |
|---|
| Številčenje: | Vol. , iss. |
|---|
| Izvor: | ZDA |
|---|
| PID: | 20.500.12556/DiRROS-25083  |
|---|
| UDK: | 53 |
|---|
| ISSN pri članku: | 2379-3694 |
|---|
| DOI: | 10.1021/acssensors.5c02057  |
|---|
| COBISS.SI-ID: | 263994627  |
|---|
| Avtorske pravice: | © 2025 The Authors. |
|---|
| Opomba: | Nasl. z nasl. zaslona;
Opis vira z dne 8. 1. 2026;
|
|---|
| Datum objave v DiRROS: | 09.01.2026 |
|---|
| Število ogledov: | 63 |
|---|
| Število prenosov: | 25 |
|---|
| Metapodatki: |  |
|---|
|
:
|
Kopiraj citat |
|---|
| | | | Objavi na: |  |
|---|
Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše
podrobnosti ali sproži prenos. |