Naslov:Re-evaluating restrained shrinkage tests for sustainable sprayed concrete tunnel linings
Avtorji:ID Xu, Zhongyu (Avtor)
ID Hanžič, Lucija (Avtor)
ID Asche, Harry (Avtor)
ID Karlovšek, Jurij (Avtor)
Datoteke:URL URL - Izvorni URL, za dostop obiščite https://doi.org/10.1201/9781003559047-66
 
.pdf PDF - Predstavitvena datoteka, prenos (476,48 KB)
MD5: C9F839F2D91635224DE3C05A1F3D9880
 
Jezik:Angleški jezik
Tipologija:1.08 - Objavljeni znanstveni prispevek na konferenci
Organizacija:Logo ZAG - Zavod za gradbeništvo Slovenije
Povzetek:The demand for tunnelling and underground construction is steadily increasing, alongside growing considerations for carbon emission reduction in tunnelling projects. Using sprayed concrete as a prominent ground support mechanism for the sequential excavation method is also undergoing low-carbon transition with improved resource efficiency. Enhancing the durability of sprayed concrete linings for structural support and water tightness is essential, particularly when used as a permanent lining, replacing conventional cast in-situ concrete for a design life exceeding 100 years. As sprayed concrete is a time-dependent material used in a time-dependent tunnelling environment, restrained shrinkage cracking in tunnel linings is a recognised issue, especially in mined tunnels in shallow or hard-rock ground with minimal ground movement. The susceptibility of sprayed concrete to restrained shrinkage cracking poses challenges to low-carbon transition, impacting the efficacy and longevity of tunnel linings. Excessive crack widths in tunnel projects often lead to non-conformances, requiring time-consuming repairs and affecting project delivery. However, current design methods for permanent sprayed concrete linings inadequately consider the effects of restrained shrinkage, particularly with sprayed concrete containing reinforcement fibres and accelerators. This paper examines the features that should be included in the restrained shrinkage test for tunnel lining applications, and proposes an improvement in detecting crack initiation and determining the optimal number of measurement points form when multiple cracks form with a finite element analysis. The analysis results showed the possibility of detecting the onset of cracking and crack location with multiple measurement points by interpreting the response of each measurement point.
Ključne besede:tunnel linings, sprayed concrete, restrained shinkage, large ring test
Status publikacije:Objavljeno
Verzija publikacije:Objavljena publikacija
Datum objave:08.05.2025
Založnik:CRC Press
Leto izida:2025
Št. strani:Str. 509-516
PID:20.500.12556/DiRROS-23646 Novo okno
UDK:620.1/.2
DOI:10.1201/9781003559047-66 Novo okno
COBISS.SI-ID:248857603 Novo okno
Avtorske pravice:© 2025 The Author(s)
Datum objave v DiRROS:19.09.2025
Število ogledov:339
Število prenosov:141
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
  
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del monografije

Naslov:Geotechnical engineering challenges to meet current and emerging needs of society : proceedings of the XVIII European Conference on Soil Mechanics and Geotechnical Engineering, 26–30 August 2024, Lisbon, Portugal
Uredniki:Nuno Guerra
Kraj izida:London
Založnik:CRC Press
Leto izida:2024
ISBN:978-1-003-43174-9
COBISS.SI-ID:212003843 Novo okno

Licence

Licenca:CC BY-NC-ND 4.0, Creative Commons Priznanje avtorstva-Nekomercialno-Brez predelav 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by-nc-nd/4.0/deed.sl
Opis:Najbolj omejujoča licenca Creative Commons. Uporabniki lahko prenesejo in delijo delo v nekomercialne namene in ga ne smejo uporabiti za nobene druge namene.

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:tunelske obloge, brizgani beton, ovirano krčenje, test z obročem velikih dimenzij