| Naslov: | Protein stacking on the APTES-functionalized pyrochlore ▫$Bi_2Ru_2O_7$▫ clusters for ultrasensitive and selective immunosensing |
|---|
| Avtorji: | ID Tasić, Nikola (Avtor) ID Vranešič, Nika (Avtor) ID Metarapi, Dino (Avtor) ID Mervič, Kristina (Avtor) ID Žunić, Milan (Avtor) ID Dapčević, Aleksandra (Avtor) ID Finšgar, Matjaž (Avtor) ID Hočevar, Samo B. (Avtor) |
| Datoteke: | URL - Izvorni URL, za dostop obiščite https://pubs.acs.org/doi/10.1021/acsami.4c17869
PDF - Predstavitvena datoteka, prenos (1,47 MB) MD5: 6ED82F843731F978E824727C0F952C75
|
|---|
| Jezik: | Angleški jezik |
|---|
| Tipologija: | 1.01 - Izvirni znanstveni članek |
|---|
| Organizacija: | KI - Kemijski inštitut
|
|---|
| Povzetek: | With their unique physicochemical properties, such as metallic-like conductivity, favorable (electro)catalytic properties, electrochemical stability, and ease of functionalization, pyrochlores have found applications in various fields such as solid oxide fuel cells, batteries, thick film resistors, and temperature sensors; however, there are no reports on their application in electrochemical immunosensing. In this study, we exploited the (electro)catalytic nature and stability of the pyrochlore Bi2Ru2O7 clusters silanized with (3-aminopropyl)triethoxysilane (APTES) to demonstrate their potential for the effective stacking of functional proteins. Characterization of the clusters by XPS disclosed a dual environment of Bi, also indicating the presence of Bi2O3 alongside APTES-Bi2Ru2O7 clusters and, importantly, the predominant involvement of pyrochlore moieties in subsequent protein stacking. After stacking protein A and antibodies, the immunosensor revealed a nearly interference-free operation, high sensitivity, a detection limit of 118 fM SARS-CoV-2 spike protein, and operation in a wide examined concentration range of 10−5−10−1 μg mL−1 with an r2 of 0.98. In combination with a short incubation time of 30 min, the pyrochlore-based immunosensor provides a solid platform for future point-of-need applications. |
|---|
| Ključne besede: | Bi2Ru2O7 pyrochlore, APTES, SARS-CoV-2, spike protein, immunosensors, electrochemical |
|---|
| Status publikacije: | Objavljeno |
|---|
| Verzija publikacije: | Objavljena publikacija |
|---|
| Datum objave: | 01.01.2025 |
|---|
| Založnik: | American Chemical Society |
|---|
| Leto izida: | 2025 |
|---|
| Št. strani: | str. 10792-10801 |
|---|
| Številčenje: | Vol. 17, iss. 7 |
|---|
| Izvor: | ACS applied materials & interfaces |
|---|
| PID: | 20.500.12556/DiRROS-21753  |
|---|
| UDK: | 543.384 |
|---|
| ISSN pri članku: | 1944-8252 |
|---|
| DOI: | 10.1021/acsami.4c17869  |
|---|
| COBISS.SI-ID: | 228608771  |
|---|
| Avtorske pravice: | © 2025 The Authors. Published by American Chemical Society |
|---|
| Opomba: | Nasl. z nasl. zaslona;
Soavtorji: Nika Vranešič, Dino Metarapi, Kristina Mervič, Milan Žunić, Aleksandra Dapčević, Matjaž Finšgar, Samo B. Hočevar;
Opis vira z dne 11. 3. 2025;
|
|---|
| Datum objave v DiRROS: | 24.03.2025 |
|---|
| Število ogledov: | 669 |
|---|
| Število prenosov: | 403 |
|---|
| Metapodatki: |  |
|---|
|
:
|
Kopiraj citat |
|---|
| | | | Objavi na: |  |
|---|
Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše
podrobnosti ali sproži prenos. |