Naslov:The impact of a thermal insulation layer on the seismic performance of energy-efficient buildings
Avtorji:ID Lenart, Stanislav (Avtor)
ID Karumanchi, Siva Ram (Avtor)
Datoteke:URL URL - Izvorni URL, za dostop obiščite https://doi.org/10.3208/jgssp.v10.OS-37-07
 
.pdf PDF - Predstavitvena datoteka, prenos (854,84 KB)
MD5: E652257B31C088D76A5E401A8FDCC29E
 
Jezik:Angleški jezik
Tipologija:1.08 - Objavljeni znanstveni prispevek na konferenci
Organizacija:Logo ZAG - Zavod za gradbeništvo Slovenije
Povzetek:Energy-efficient homes are constructed with a continuous and uniform thermal envelope and are commonly built on top of a thermal insulation (TI) layer that encloses the entire building. Lightweight aggregates such as foamed glass aggregate, expanded clay aggregate, and extruded polystyrene (XPS) insulation boards are commonly used as materials for the TI layer to prevent thermal bridging at the ground floor slab. However, the reinforced concrete slab foundation above the TI layer is susceptible to horizontal sliding during seismic loading. To improve the seismic behavior of buildings founded on TI layers, this study discussed the shear stiffness and damping characteristics of lightweight aggregates and three types of XPS boards through laboratory tests available in the literature. A 2-dimensional numerical analysis is performed, and the corresponding validation results of the simulations are presented. The effect of TI layers on the seismic performance of buildings constructed with TI layers made from these materials is assessed. A comparative analysis of various interface conditions of the TI materials under seismic loading is also conducted. Overall, this research aims to enhance the resilience and sustainability of energy-efficient homes by investigating the impact of TI layers on their seismic performance. The findings provide valuable insights for designing more robust structures that can withstand seismic events.
Ključne besede:energy-efficient buildings, thermal insulation, extruded polystyrene (XPS), finite element analysis, foamed glass aggregate, seismic response
Status publikacije:Objavljeno
Verzija publikacije:Objavljena publikacija
Datum objave:01.01.2024
Založnik:Japanese Geotechnical Society
Leto izida:2024
Št. strani:Str. 1813-1818
PID:20.500.12556/DiRROS-21271 Novo okno
UDK:691:699.8
ISSN pri članku:1755-1315
DOI:10.3208/jgssp.v10.OS-37-07 Novo okno
COBISS.SI-ID:222920963 Novo okno
Datum objave v DiRROS:21.01.2025
Število ogledov:624
Število prenosov:373
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
  
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del zbornika

Naslov:8th International Conference on Earthquake Geotechnical Engineering (8ICEGE)
COBISS.SI-ID:222918659 Novo okno

Gradivo je del revije

Naslov:Japanese Geotechnical Society special publication
Skrajšan naslov:Jpn. Geotech. Soc. spec. publ.
Založnik:Japanese Geotechnical Society
ISSN:2188-8027
COBISS.SI-ID:222874371 Novo okno

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:energetsko učinkovite stavbe, toplotna izolacija, ekstrudirani polistiren (XPS), analiza končnih elementov, agregat iz penastega stekla, potresni odziv