Digitalni repozitorij raziskovalnih organizacij Slovenije

Izpis gradiva
A+ | A- | Pomoč | SLO | ENG

Naslov:List of criteria the reference materials have to meet for use in validation studies : grant agreement N. 773139, DELIVERABLE N° 3.1 – V2
Avtorji:ID Chappé, Anne-Marie (Avtor)
ID Chabirand, A (Avtor)
ID Dahlin, P. (Avtor)
ID Krom, C. de (Avtor)
ID Dreo, Tanja (Avtor)
ID Gentit, Pascal (Avtor)
ID Laurenson, L (Avtor)
ID Peter, F. (Avtor)
ID Spadaro, D. (Avtor)
ID Vlugt, René van der (Avtor)
ID Veen, E. van (Avtor)
ID Westenberg, Marcel (Avtor)
Datoteke:.pdf PDF - Predstavitvena datoteka, prenos (1,99 MB)
MD5: 18900B26857688C6099D29BF5BBB8396
 
Jezik:Angleški jezik
Tipologija:2.13 - Elaborat, predštudija, študija
Organizacija:Logo NIB - Nacionalni inštitut za biologijo
Povzetek:A list of general minimum criteria was developed to be used in preparation of reference materials to be used in interlaboratory testing, including validations through test performance studies. The list was based on previously identified criteria in standards including ISO standards, EPPO guidelines, deliverables of relevant projects, related fields, and own experience of project partners. Several additional criteria were proposed: ‘availability’, ‘purity’ and ‘commutability’. These criteria result from a series of discussions, taking into account previous work and relevant international standards. Where relevant, each criterion was first defined as a series of levels from the highest to lowest ranking with the lowest ranking considered to be the minimum. Depending on the intended use, the reference material may need to fulfil higher levels of selected criteria or some criteria may not be relevant at all. The criteria were tested by the organizers of the TPS in round 1 of validation within VALITEST project which include bacteria, viruses, nematodes and fungi. The systematic and structured approach of describing RMs was found to be useful in promoting transparent descriptions of the RMs used and comparability of TPSs, as well as a step toward implementing FAIR data principles. The criteria defined here are applicable, potentially with minor modification, beyond the scope of this deliverable and project to other pests and other uses of RMs
Ključne besede:pests, tests
Status publikacije:Objavljeno
Verzija publikacije:Objavljena publikacija
Datum objave:01.03.2019
Kraj izida:[S. l.
Kraj izvedbe:[S. l.
Založnik:s. n.
Leto izida:2019
Leto izvedbe:2019
Št. strani:IV, 19 str.
PID:20.500.12556/DiRROS-20307 Novo okno
UDK:632
COBISS.SI-ID:5021775 Novo okno
Datum objave v DiRROS:03.09.2024
Število ogledov:29
Število prenosov:843
Metapodatki:XML RDF-CHPDL DC-XML DC-RDF
:
Kopiraj citat
  
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je financirano iz projekta

Financer:EC - European Commission
Številka projekta:773139
Naslov:Validation of diagnostic tests to support plant health
Akronim:VALITEST

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Nazaj