Digitalni repozitorij raziskovalnih organizacij Slovenije

Izpis gradiva
A+ | A- | Pomoč | SLO | ENG

Naslov:Comparison and transfer testing of multiplex ligation detection methods for GM plants
Avtorji:ID Ujhelyi, Gabriella (Avtor)
ID van Dijk, Jeroen P. (Avtor)
ID Prins, Theo W. (Avtor)
ID Voorhuijzen, Marleen (Avtor)
ID Van Hoef, Angeline (Avtor)
ID Beenen, Henriek G. (Avtor)
ID Morisset, Dany (Avtor)
ID Gruden, Kristina (Avtor)
ID Kok, Esther (Avtor)
Datoteke:URL URL - Izvorni URL, za dostop obiščite http://dx.doi.org/10.1186/1472-6750-12-4
 
.pdf PDF - Predstavitvena datoteka, prenos (425,18 KB)
MD5: 4D021A0F9F4988B60F8919167796781C
 
Jezik:Angleški jezik
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:Logo NIB - Nacionalni inštitut za biologijo
Povzetek:Background With the increasing number of GMOs on the global market the maintenance of European GMO regulations is becoming more complex. For the analysis of a single food or feed sample it is necessary to assess the sample for the presence of many GMO-targets simultaneously at a sensitive level. Several methods have been published regarding DNA-based multidetection. Multiplex ligation detection methods have been described that use the same basic approach: i) hybridisation and ligation of specific probes, ii) amplification of the ligated probes and iii) detection and identification of the amplified products. Despite they all have this same basis, the published ligation methods differ radically. The present study investigated with real-time PCR whether these different ligation methods have any influence on the performance of the probes. Sensitivity and the specificity of the padlock probes (PLPs) with the ligation protocol with the best performance were also tested and the selected method was initially validated in a laboratory exchange study. Results Of the ligation protocols tested in this study, the best results were obtained with the PPLMD I and PPLMD II protocols and no consistent differences between these two protocols were observed. Both protocols are based on padlock probe ligation combined with microarray detection. Twenty PLPs were tested for specificity and the best probes were subjected to further evaluation. Up to 13 targets were detected specifically and simultaneously. During the interlaboratory exchange study similar results were achieved by the two participating institutes (NIB, Slovenia, and RIKILT, the Netherlands). Conclusions From the comparison of ligation protocols it can be concluded that two protocols perform equally well on the basis of the selected set of PLPs. Using the most ideal parameters the multiplicity of one of the methods was tested and 13 targets were successfully and specifically detected. In the interlaboratory exchange study it was shown that the selected method meets the 0.1% sensitivity criterion. The present study thus shows that specific and sensitive multidetection of GMO targets is now feasible.
Ključne besede:geneticallz modified organisms, GMO
Status publikacije:Objavljeno
Verzija publikacije:Objavljena publikacija
Datum objave:12.01.2012
Leto izida:2012
Št. strani:str. 1-12
Številčenje:Vol. 12, no. 4
PID:20.500.12556/DiRROS-20035 Novo okno
UDK:604
ISSN pri članku:1472-6750
DOI:10.1186/1472-6750-12-4 Novo okno
COBISS.SI-ID:2503503 Novo okno
Opomba:Soavtorji: Jeroen P. van Dijk, Theo W. Prins, Marleen M. Voorhuijzen, A. M. Angeline Van Hoef, Henriek G. Beenen, Dany Morisset, Kristina Gruden and Esther J. Kok; Popis vira z dne 7.2.2012;
Datum objave v DiRROS:05.08.2024
Število ogledov:20
Število prenosov:15
Metapodatki:XML RDF-CHPDL DC-XML DC-RDF
:
Kopiraj citat
  
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del revije

Naslov:BMC biotechnology
Skrajšan naslov:BMC Biotechnol
Založnik:BioMed Central
ISSN:1472-6750
COBISS.SI-ID:2433812 Novo okno

Gradivo je financirano iz projekta

Financer:EC - European Commission
Številka projekta:221218
Naslov:Multiplex detection of (un)authorized GMOs in food and feed
Akronim:GMULTI

Financer:EC - European Commission
Številka projekta:007158
Naslov:GM and non-GM supply chains: their CO-EXistence and TRAceability
Akronim:CO-EXTRA

Financer:Drugi - Drug financer ali več financerjev
Program financ.:6th Framework Programme of the European Union; the Dutch Ministry of Economic Affairs, Agriculture and Innovation
Številka projekta:FOOD-CT-2005-006942
Naslov:-TRAcing food Commodities in Europe, project
Akronim:TRACE

Licence

Licenca:CC BY 2.0, Creative Commons Priznanje avtorstva 2.0 Generična
Povezava:https://creativecommons.org/licenses/by/2.0/deed.sl
Opis:Dovoljuje kopiranje in razširjanje vsebin v kakršnemkoli mediju in obliki. Dovoljuje remixanje, urejanje, predelava in vključevanje vsebine v lastna dela v vse namene, tudi komercialne. Primerno morate navesti avtorja, povezavo do licence in označiti spremembe, če so kakšne nastale. To lahko storite na kakršenkoli razumen način, vendar ne na način, ki bi namigoval na to, da dajalec licence podpira vas ali vašo uporabo dela. Ne smete uporabiti pravnih določil ali tehničnih ukrepov, ki bi pravno omejili ali onemogočilo druge, da bi storili karkoli, kar licenca dovoli.

Nazaj