Digitalni repozitorij raziskovalnih organizacij Slovenije

Izpis gradiva
A+ | A- | Pomoč | SLO | ENG

Naslov:First experience with a novel luminescence-based optical sensor for measurement of oxygenation in tumors
Avtorji:ID Jarm, Tomaž (Avtor)
ID Lešničar, Hotimir (Avtor)
ID Serša, Gregor (Avtor)
ID Miklavčič, Damijan (Avtor)
Datoteke:.pdf PDF - Predstavitvena datoteka, prenos (231,19 KB)
MD5: E15409B69E537940419664C275388EEC
 
Jezik:Angleški jezik
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:Logo OI - Onkološki inštitut Ljubljana
Povzetek:Background. The purpose of this preliminary study was to evaluate a novel luminescence-based fiber-optic sensor (OxyLite system) for the measurement of partial pressure of oxygen (pO2) in tumors and for the detection of changes inpO2 as a function of time. The new method was used simultaneously with the laser Doppler flowmetry method for the measurement of relative tissue perfusion. Materials and methods. Blood perfusion and pO2 were measured continuously via fiber-optic sensors inserted into SA-1 tumors in anesthetizedAžJ mice. The changes in blood flow and oxygenation of tumors wereinduced by transient changes of the parameters of anesthesia and by injection of a vasoactive drug hydralazine. Results. Both optical methods usedin the study successfully detected the induced changes in blood flow and pO2. The measurements of pO2 were well correlated with measurements of microcirculatory blood perfusion. In the majority of pO2 measurements, we observed an unexpected behavior of the signal during the stabilization processimmediately after the insertion of the probe into tumor. This behaviourof the pO2 signal was most probably caused by local tissue damage induced by the insertion of the probe. Conclusion. The novel luminescence-based optical oximetry can reliably detect local pO2 changes in tumors as a function of time but some aspects of prolonged pO2 measurement by this method require further investigation.
Ključne besede:sarcoma experimental, blood supply, laser-doppler flowmetry, oxygen, luminiscence
Status publikacije:Objavljeno
Verzija publikacije:Objavljena publikacija
Datum objave:01.12.2001
Založnik:Slovenian Medical Association - Slovenian Association of Radiology, Nuclear Medicine Society, Slovenian Society far Radiotherapy and Oncology, and Slovenian Cancer Society
Leto izida:2001
Št. strani:str. 277-291
Številčenje:Vol. 35, no. 4
Izvor:Ljubljana
PID:20.500.12556/DiRROS-17992 Novo okno
UDK:616-006
ISSN pri članku:1318-2099
COBISS.SI-ID:2531156 Novo okno
Avtorske pravice:by Authors
Datum objave v DiRROS:25.01.2024
Število ogledov:264
Število prenosov:79
Metapodatki:XML RDF-CHPDL DC-XML DC-RDF
:
Kopiraj citat
  
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del revije

Naslov:Radiology and oncology
Skrajšan naslov:Radiol. oncol.
Založnik:Slovenian Medical Society - Section of Radiology, Croatian Medical Association - Croatian Society of Radiology
ISSN:1318-2099
COBISS.SI-ID:32649472 Novo okno

Sekundarni jezik

Jezik:Slovenski jezik
Naslov:Prve izkušnje z novo luminiscenčno optično metodo za merjenje oksigenacije v tumorjih
Ključne besede:eksperimentalni sarkom, pretok krvi, metoda laser Doppler, oksigenacija, luminescenca


Nazaj