Digitalni repozitorij raziskovalnih organizacij Slovenije

Izpis gradiva
A+ | A- | Pomoč | SLO | ENG

Naslov:Feasibility of remote blood pressure estimation via narrow-band multi-wavelength pulse transit time
Avtorji:ID Slapničar, Gašper (Avtor)
ID Wang, Wenjin (Avtor)
ID Luštrek, Mitja (Avtor)
Datoteke:URL URL - Izvorni URL, za dostop obiščite https://dl.acm.org/doi/10.1145/3597302
 
.pdf PDF - Predstavitvena datoteka, prenos (1,06 MB)
MD5: 15B73BDBD853A3D18930CE55FD3AA370
 
Jezik:Angleški jezik
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:Logo IJS - Institut Jožef Stefan
Povzetek:Contact-free sensing gained much traction in the past decade. While remote monitoring of some parameters (heart rate) is approaching clinical levels of precision, others remain challenging (blood pressure). We investigated the feasibility of estimating blood pressure (BP) via pulse transit time (PTT) in a novel remote single-site manner, using a modified RGB camera. A narrow-band triple band-pass filter allowed us to measure the PTT between different skin layers, harvesting information from green and near-infrared wavelengths. The filter minimizes the inter-channel influence and band overlap, however some overlap remains within the filter bands. We further resolve this using a color-channel model and a novel channel-separation method. Using the proposed setup and algorithm, we obtained multi-wavelength (MW) PTTs in an experiment inducing BP changes to 9 subjects. The results showed good absolute Pearson’s correlation coefficient between both MW PTT and systolic BP (R = 0.61, p = 0.08) as well as diastolic BP (R = 0.54, p = 0.05), pointing to feasibility of the proposed novel remote MW BP estimation via PTT. This was further confirmed in a leave-one-subject-out experiment, where a simple Random Forest regression model achieved mean absolute errors of 3.59 and 2.63 mmHg for systolic and diastolic BP respectively.
Status publikacije:Objavljeno
Verzija publikacije:Objavljena publikacija
Datum objave:01.01.2023
Založnik:Association for Computing Machinery
Leto izida:2023
Št. strani:str. 1-20
Izvor:Združene države Amerike
PID:20.500.12556/DiRROS-16729 Novo okno
UDK:63:004
ISSN pri članku:1550-4867
DOI:doi.org/10.1145/3597302 Novo okno
COBISS.SI-ID:159807235 Novo okno
Avtorske pravice:© 2023 Copyright held by the owner/author(s).
Opomba:Nasl. z nasl. zaslona; Opis vira z dne 26. 7. 2023;
Datum objave v DiRROS:27.07.2023
Število ogledov:362
Število prenosov:180
Metapodatki:XML RDF-CHPDL DC-XML DC-RDF
:
Kopiraj citat
  
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del revije

Naslov:ACM transactions on sensor networks
Založnik:Association for Computing Machinery
ISSN:1550-4867
COBISS.SI-ID:521924633 Novo okno

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:spremenjene kamere RGB, kanali, zbiranje, podatki, krvni tlak, meritve


Nazaj