Digitalni repozitorij raziskovalnih organizacij Slovenije

Izpis gradiva
A+ | A- | SLO | ENG

Naslov:Quantification of the link between timed up-and-go test subtasks and contractile muscle properties
Avtorji:Ziegl, Andreas (Avtor)
Hayn, Dieter (Avtor)
Kastner, Peter (Avtor)
Fabiani, Ester (Avtor)
Šimunič, Boštjan (Avtor)
Löffler, Kerstin (Avtor)
Weidinger, Lisa (Avtor)
Brix, Bianca (Avtor)
Goswami, Nandu (Avtor)
Schreier, Günter (Avtor)
Jezik:Angleški jezik
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:Logo ZRS Koper - Znanstveno-raziskovalno središče Koper / Centro di Ricerche Scientifiche Capodistria
Povzetek:Frailty and falls are a major public health problem in older adults. Muscle weakness of the lower and upper extremities are risk factors for any, as well as recurrent falls including injuries and fractures. While the Timed Up-and-Go (TUG) test is often used to identify frail members and fallers, tensiomyography (TMG) can be used as a non-invasive tool to assess the function of skeletal muscles. In a clinical study, we evaluated the correlation between the TMG parameters of the skeletal muscle contraction of 23 elderly participants (22 f, age 86.74 % 7.88) and distance-based TUG test subtask times. TUG tests were recorded with an ultrasonic-based device. The sit-up and walking phases were significantly correlated to the contraction and delay time of the muscle vastus medialis (% = 0.55%0.80, p < 0.01). In addition, the delay time of the muscles vastus medialis (% = 0.45, p = 0.03) and gastrocnemius medialis (% = %0.44, p = 0.04) correlated to the sit-down phase. The maximal radial displacements of the biceps femoris showed significant correlations with the walk-forward times (% = %0.47, p = 0.021) and back (% = %0.43, p = 0.04). The association of TUG subtasks to muscle contractile parameters, therefore, could be utilized as a measure to improve the monitoring of elderly people%s physical ability in general and during rehabilitation after a fall in particular. TUG test subtask measurements may be used as a proxy to monitor muscle properties in rehabilitation after long hospital stays and injuries or for fall prevention.
Ključne besede:timed up-and-go test, tensiomyography, biomedical engineering, biomedical sensors, health
Leto izida:2021
UDK:612.74:796.012.1
ISSN pri članku:1424-8220
COBISS_ID:80043267 Povezava se odpre v novem oknu
DOI:10.3390/s21196539 Povezava se odpre v novem oknu
Opombe:Nasl. z nasl. zaslona; Soavtorji: Dieter Hayn, Peter Kastner, Ester Fabiani, Boštjan Šimunič, Kerstin Löffler, Lisa Weidinger, Bianca Brix , Nandu Goswami, Schreier Günter; Opis vira z dne 11. 10. 2021; Članek št. 6539;
Število ogledov:167
Število prenosov:125
Datoteke:.pdf PDF - Predstavitvena datoteka, prenos (1,34 MB)
URL URL - Izvorni URL, za dostop obiščite https://www.mdpi.com/1424-8220/21/19/6539
 
Nadgradivo:Sensors
MDPI
 
Metapodatki:XML RDF-CHPDL DC-XML DC-RDF
Avtorske pravice:© 2021 by the authors
:
  
Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.


Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.
Začetek licenciranja:30.09.2020

Nazaj