Digitalni repozitorij raziskovalnih organizacij Slovenije

Iskanje po repozitoriju
A+ | A- | Pomoč | SLO | ENG

Iskalni niz: išči po
išči po
išči po
išči po

Možnosti:
  Ponastavi


Iskalni niz: "ključne besede" (tensile test) .

1 - 3 / 3
Na začetekNa prejšnjo stran1Na naslednjo stranNa konec
1.
Susceptibility of X17CrNi16-2 martensitic stainless steel to hydrogen embrittlement after conventional and deep cryogenic heat treatment
Mirjam Bajt Leban, Bojan Zajec, Bojan Podgornik, Črtomir Donik, Patricia Jovičević Klug, Miha Hren, Andraž Legat, 2024, izvirni znanstveni članek

Povzetek: A low carbon/ high chromium martensitic stainless steel, X17CrNi16-2, was heat treated using two different hardening and tempering regimes (1050 ◦ C/480 ◦ C or 980 ◦C/600 ◦C) — promoting either a high strength or high toughness state, respectively and further combined with deep cryogenic treatment (DCT) at 196 ◦C for 24 h. Over recent years DCT has been recognized as a promising technique to improve the properties of steel, predominantly with respect to its tensile strength, toughness and wear resistance. The influence of DCT on the hydrogen embrittlement resistance of martensitic stainless steel has not yet, however, been reported. A slow strain rate tensile test (SSRT) with simultaneous cathodic hydrogen charging was selected as the method to assess potential susceptibility to hydrogen embrittlement (HE). Relatively low-intensity hydrogen charging, utilizing a constant current density of 0.1 mA/cm2, in a non-corrosive, slightly alkaline buffer solution, led to a clear reduction in the ultimate tensile stress. This reduction, and therefore the HE susceptibility, was more pronounced in the steel with a higher strength (i.e. that subject to the 1050 ◦C/ 480 ◦C heat treatment condition). Furthermore, DCT did not appear to have any impact on the steel’s mechanical properties in the presence of hydrogen. Fractographic analysis showed clear evidence of HE in the hydrogen-charged specimens. This paper presents results of the SSRT tests and further fractography results, and discusses the impact of conventional and deep cryogenic treatment on HE susceptibility.
Ključne besede: martensitic stainless steel, deep cryogenic treatment, hydrogen embrittlement, slow strain rate tensile test
Objavljeno v DiRROS: 23.05.2024; Ogledov: 86; Prenosov: 88
.pdf Celotno besedilo (17,73 MB)
Gradivo ima več datotek! Več...

2.
Mechanical properties of high carbon low-density steels
Jiri Hajek, Zbyšek Nový, Ludmila Kucerova, Hana Jirková, Črtomir Donik, Zdeňek Jansa, 2023, izvirni znanstveni članek

Ključne besede: low density steels, heat treatment, tensile test
Objavljeno v DiRROS: 02.02.2024; Ogledov: 203; Prenosov: 90
.pdf Celotno besedilo (10,85 MB)
Gradivo ima več datotek! Več...

3.
Iskanje izvedeno v 0.11 sek.
Na vrh