Digital repository of Slovenian research organisations

Search the repository
A+ | A- | Help | SLO | ENG

Query: search in
search in
search in
search in

Options:
  Reset


Query: "keywords" (finite-element method) .

1 - 6 / 6
First pagePrevious page1Next pageLast page
1.
2.
Lessons learned from the monitoring of retaining structures, built in demanding geotechnical conditions in Slovenia
Pavel Žvanut, Janko Logar, 2019, published scientific conference contribution

Abstract: A typical retaining structure built with large-diameter bored piles in soft clastic rock, and sup-ported by pre-stressed permanent ground anchors, is discussed. Step-by-step back analyses were performed. A simplified geological structure was first used in the analyses, together with a simple Mohr-Coulomb model. The results were compared with more complex analyses using a Hardening Soil model and a more detailed geological structure. Much better results were obtained with the use of the HS model, which is more suitable for the modelling of rock of such a type, but even with the use of the MC model the final results were quite good, making the use of the observational method attractive for engineers.
Keywords: geotechnics, gretaining structures, bored piles, numerical modelling, finite element method, observational method
Published in DiRROS: 27.03.2024; Views: 114; Downloads: 55
.pdf Full text (1,67 MB)
This document has many files! More...

3.
Numerical modeling in electroporation-based biomedical applications
Nataša Pavšelj, Damijan Miklavčič, 2008, original scientific article

Abstract: Background. Numerous experiments have to be performed before a biomedical application is put to practical use in clinical environment. As a complementary work to in vitro, in vivo and medical experiments, we can use analytical and numerical models to represent, as realistically as possible, real biological phenomena of, in our case, electroporation. In this way we canevaluate different electrical parameters in advance, such as pulse amplitude, duration, number of pulses, or different electrode geometries. Suchnumerical models can contribute significantly to the understanding of an experiment and treatment planning as well as to the design of new electroporation devices and electrodes. Methods. We used commercially available modeling software, based on finite element method. We constructed a model of a subcutaneous tumor during electrochemotherapy (EMAS) and a model ofskin during gene electrotransfer (COMSOL Multiphysics). Tissue-electrode geometries, pulse parameters and currentvoltage measurements from in vivo experiments were used to develop and validate the models. Results. To describeadequately our in vivo observations, a tissue conductivity increase during electroporation was included in our numerical models. The output currents of the models were compared to the currents and the voltages measuredduring in vivo experiments and a good agreement was obtained. Also, when comparing the voltages needed for a successful electropermeabilization assuggested by the models, to voltages applied in experiments and achieving a successful electrochemotherapy or in vivo gene electrotransfer, good agreementcan be observed. Conclusions. Modeling of electric current and electric field distribution during cell and tissue electroporation proves to be helpful in describing different aspects of the process and allowing us to design electrodes and electroporation protocols as a part of treatment planning.
Keywords: electroporation, gene electrotransfer, electrochemotherapy, subcutaneous tumor, finite-element method
Published in DiRROS: 07.03.2024; Views: 119; Downloads: 35
.pdf Full text (549,62 KB)

4.
5.
3D finite element analysis of a concrete dam behavior under changing hydrostatic load : a case study
Pavel Žvanut, 2022, original scientific article

Abstract: In this study, a large arch-gravity Moste Dam was analyzed, where an automated system for the measurements of horizontal displacements of the upper part of the dam was established. Two-dimensional (2D) and three-dimensional (3D) analyses of dam behavior, taking into account the earth pressures and the hydrostatic load, using the finite element method (FEM)-based computer program DIANA, were performed. The influence of lowering the water level of the reservoir by 6.2 m, on the horizontal displacements of the upper part of the dam, at stationary temperature conditions, was investigated. It was found that the results of the performed 2D and 3D FEM analyses fitted in very well with the result of experimentally determined measurement of horizontal displacements (which was 0.48 mm in the upstream direction) that was obtained using a hanging pendulum. An additional comparison of the results of 3D calculations showed that the finite element mesh density had a small effect on the calculated horizontal displacements.
Keywords: concrete dam, finite element method, material properties, structure behavior, measuring instruments, monitoring, ime series analysis, horizontal displacements, hydrostatic pressure
Published in DiRROS: 21.06.2023; Views: 346; Downloads: 194
.pdf Full text (5,35 MB)
This document has many files! More...

6.
Search done in 0.17 sec.