Title:The influence of late gadolinium enhancement cardiac magnetic resonance image analysis imprecision on myocardial damage quantification in patients with myocarditis : a pilot study
Authors:ID Kralj, Lana (Author)
ID Černe Čerček, Andreja (Author)
ID Gomišček, Alja (Author)
ID Kirn, Borut (Author)
Files:.pdf PDF - Presentation file, download (2,14 MB)
MD5: 82C45017F8D5FDF7B21DD5809BC313B3
 
URL URL - Source URL, visit https://www.mdpi.com/2076-3417/14/1/117
 
Language:English
Typology:1.01 - Original Scientific Article
Organization:Logo UKC LJ - Ljubljana University Medical Centre
Abstract:Background: Myocardial damage in myocarditis is assessed through late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR). Variability in quantifying myocarditis extent results from imprecise image segmentation and inconclusive data on quantification method selection. To improve analysis precision, segmentation steps are systematically ranked based on their inherent risks of error. Additionally, data on two distinct quantification methods are presented. Methods: Using newly developed software, four experts analyzed five LGE-CMR left ventricular (LV) short-axis (SAx) images of myocarditis patients in three sessions. Regions of interest (ROIs) (myocardial (ROImyoc), reference (ROIref), and exclusion region (ROIexcl)) were identified and used to calculate LGE extent with 3σ (intensity above three standard deviations (σ) in reference) and the full width at half maximum (FWHM) method (intensity above 50% of maximum signal in reference). The reference LGE extent was calculated and the influence of the ROIs on LGE extent variability was determined. Interobserver and intraobserver variability were evaluated as 1-intraclass correlation coefficient (ICC). Results: LGE extent variability was 6.2 ± 0.6% for 3σ and 4.0 ± 0.6% for FWHM. The contributions of ROImyoc, ROIref, and ROIexcl were 1.5 ± 0.2%, 2.7 ± 0.4%, and 2 ± 0.3%, respectively, for 3σ, and 1.1 ± 0.1%, 1.6 ± 0.4%, and 1.3 ± 0.3%, respectively, for FWHM. LGE extent was lower in FWHM. Interobserver variability was 0.56 for 3σ and 0.43 for FWHM. The intraobserver variability was higher for the 3σ method in all four observers. Conclusion: ROIref selection contributed most to LGE extent variability. FWHM yielded lower LGE extent and lower inter- and intraobserver variability. Due to low statistical significance, the findings are only partially confirmed.
Keywords:myocarditis, cardiac magnetic resonance, variability, full width at half maximum, thresholding methods, segmentation
Publication status:Published
Publication version:Version of Record
Year of publishing:2024
Number of pages:str. 1-11
Numbering:Vol. 14, iss. 1, [article no.] 117
PID:20.500.12556/DiRROS-29722 New window
UDC:616.1:612
ISSN on article:2076-3417
DOI:10.3390/app14010117 New window
COBISS.SI-ID:189025795 New window
Note: Nasl. z nasl. zaslona; Opis vira z dne 15. 3. 2024;
Publication date in DiRROS:03.06.2026
Views:36
Downloads:16
Metadata:XML DC-XML DC-RDF
:
Copy citation
  
Share:Bookmark and Share


Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Record is a part of a journal

Title:Applied sciences
Shortened title:Appl. sci.
Publisher:MDPI
ISSN:2076-3417
COBISS.SI-ID:522979353 New window

Document is financed by a project

Funder:ARIS - Slovenian Research and Innovation Agency
Project number:P3-0019-2019
Name:Aplikativna in bazična fiziologija in patofiziologija v medicini

Licences

License:CC BY 4.0, Creative Commons Attribution 4.0 International
Link:http://creativecommons.org/licenses/by/4.0/
Description:This is the standard Creative Commons license that gives others maximum freedom to do what they want with the work as long as they credit the author.

Secondary language

Language:Slovenian
Keywords:miokarditis, magnetna resonanca srca, variabilnost, polna širina na polovici maksimuma, metode določanja pragov, segmentacija