Title:A comparison of transcatheter aortic valve prosthesis platforms : Myval, Sapien, and Evolut in severe symptomatic aortic stenosis and low-moderate risk patients
Authors:ID Bunc, Matjaž (Author)
ID Steblovnik, Klemen (Author)
ID Terseglav, Simon (Author)
ID Ambrožič, Jana (Author)
ID Bervar, Mojca (Author)
ID Dimitrovska, Ljupka (Author)
ID Čerček, Miha (Author)
ID Kovač, Ana (Author)
ID Mohorko-Pleskovič, Patricija (Author)
ID Kogoj, Polonca (Author)
ID Fras, Zlatko (Author)
ID Šušteršič, Miha (Author)
ID Vrtovec, Bojan (Author)
Files:.pdf PDF - Presentation file, download (1,14 MB)
MD5: C7EDF056CDA87CFE7B1633FD507114A7
 
URL URL - Source URL, visit https://reference-global.com/article/10.2478/raon-2025-0046
 
Language:English
Typology:1.01 - Original Scientific Article
Organization:Logo UKC LJ - Ljubljana University Medical Centre
Abstract:Background This article compares the real-world performance and safety of the three transcatheter aortic valve implantation (TAVI) platforms: Myval, Sapien, and Evolut in patients with severe symptomatic aortic stenosis and low to moderate surgical risk. Patients and methods Between September 2019 and September 2023, 1053 TAVI procedures were performed in the University Medical Centre Ljubljana, Slovenia. We used propensity-score match analysis to compare the Myval, Sapien, and Evolut platforms. 180 patients were enrolled in the propensity-score matching study, 60 for each platform. The study endpoints included haemodynamic outcomes compared to baseline, in-hospital clinical safety outcomes, and all-cause mortality at 30 days and one year. Results Changes in peak aortic valve velocity, mean aortic gradient, effective orifice area, and left ventricular ejection fraction were comparable between the platforms. After propensity score matching (tri-match), the rates of stroke (3.4% vs. 3.4% vs. 0.0%, p = 0.548), life-threatening bleeding (1.7% vs. 1.7% vs. 1.7 %), periprocedural myocardial infarction (3.3% vs. 0.0% vs. 0.0%, p = 0.330), postprocedural permanent pacemaker implantation rate (11.9% vs. 10.2% vs. 15.0%, p = 0.719), all-cause mortality at 30 days (3.3% vs. 5.0% vs. 3.3%; p = 1.000) and at 1 year (8.3% vs. 8.3% vs. 10.0%, p = 0.934) were comparable between the Myval, Sapien, and Evolut series, respectively. 2 cases of moderate paravalvular regurgitation were reported, one in Myval, and one in Sapien series. Conclusions The tri-match analysis of the real-world aortic stenosis patients with low to moderate surgical risk treated with the Myval, Sapien, and Evolut series showed comparable performance, safety, efficacy, and survival.
Keywords:transcatheter aortic valve implantation, aortic stenosis, real-world comparison
Publication status:Published
Publication version:Version of Record
Year of publishing:2025
Number of pages:str. 498-509
Numbering:Vol. 59, no. 4
PID:20.500.12556/DiRROS-28371 New window
UDC:616.126
ISSN on article:1581-3207
DOI:10.2478/raon-2025-0046 New window
COBISS.SI-ID:271727107 New window
Note:Nasl. z nasl. zaslona; Opis vira z dne 16. 3. 2026;
Publication date in DiRROS:16.03.2026
Views:116
Downloads:46
Metadata:XML DC-XML DC-RDF
:
Copy citation
  
Share:Bookmark and Share


Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Record is a part of a journal

Title:Radiology and oncology
Publisher:Association of Radiology and Oncology
ISSN:1581-3207
COBISS.SI-ID:784507 New window

Licences

License:CC BY 4.0, Creative Commons Attribution 4.0 International
Link:http://creativecommons.org/licenses/by/4.0/
Description:This is the standard Creative Commons license that gives others maximum freedom to do what they want with the work as long as they credit the author.

Secondary language

Language:Slovenian
Keywords:perkutana zamenjava aortne zaklopke, aortna stenoza


Back