Naslov:Optimization of electrode position and electric pulse amplitude in electrochemotherapy
Avtorji:ID Županič, Anže (Avtor)
ID Čorović, Selma (Avtor)
ID Miklavčič, Damijan (Avtor)
Datoteke:.pdf PDF - Predstavitvena datoteka, prenos (248,14 KB)
MD5: 3ABFC7EECC043BF7E60376251CDF343A
 
Jezik:Angleški jezik
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:Logo OI - Onkološki inštitut Ljubljana
Povzetek:Background. In addition to the chemotherapeutic drug being present within the tumor during electric pulse delivery, successful electrochemotherapy requires the entire tumor volume to be subjected to a sufficiently high electric field,while the electric field in the surrounding healthy tissue is as low as possible to prevent damage. Both can be achieved with appropriate positioning of the electrodes and appropriate amplitude of electric pulses. Methods. We used 3D finite element numerical models and a genetic optimization algorithm to determine the optimum electrode configuration and optimum amplitude of electric pulses for treatment of three subcutaneous tumor models of different shapes and sizes and a realistic brain tumor model acquired from medical images. Results. In all four tumor cases, parallel needle electrode arrays were a better choice than hexagonal needle electrode arrays, since their utilization required less electric current and caused less healthy tissue damage. In addition, regardless of tumor geometry or needle electrode configuration, the optimum depth of electrode insertion was in all cases deeper than the deepest part of the tumor. Conclusions. Our optimization algorithm was able to determine the best electrode configuration in all four presented models and with further improvement it could be a useful tool in clinical electrochemotherapy treatment planning.
Status publikacije:Objavljeno
Verzija publikacije:Objavljena publikacija
Datum objave:01.01.2008
Založnik:Association of Radiology and Oncology
Leto izida:2008
Št. strani:str. 93-101
Številčenje:Letn. 42, št. 2
Izvor:Ljubljana
PID:20.500.12556/DiRROS-18352 Novo okno
UDK:616-006
ISSN pri članku:1318-2099
COBISS.SI-ID:24489945 Novo okno
Avtorske pravice:by Authors
Opomba:BSDOCID139559;
Datum objave v DiRROS:08.03.2024
Število ogledov:104
Število prenosov:34
Metapodatki:XML RDF-CHPDL DC-XML DC-RDF
:
Kopiraj citat
  
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del revije

Naslov:Radiology and oncology
Skrajšan naslov:Radiol. oncol.
Založnik:Slovenian Medical Society - Section of Radiology, Croatian Medical Association - Croatian Society of Radiology
ISSN:1318-2099
COBISS.SI-ID:32649472 Novo okno

Sekundarni jezik

Jezik:Slovenski jezik
Naslov:Optimizacija položaja elektrod in amplitude električnih pulzov v elektrokemoterapija


Nazaj