Title:Optimization of electrode position and electric pulse amplitude in electrochemotherapy
Authors:ID Županič, Anže (Author)
ID Čorović, Selma (Author)
ID Miklavčič, Damijan (Author)
Files:.pdf PDF - Presentation file, download (248,14 KB)
MD5: 3ABFC7EECC043BF7E60376251CDF343A
 
Language:English
Typology:1.01 - Original Scientific Article
Organization:Logo OI - Institute of Oncology
Abstract:Background. In addition to the chemotherapeutic drug being present within the tumor during electric pulse delivery, successful electrochemotherapy requires the entire tumor volume to be subjected to a sufficiently high electric field,while the electric field in the surrounding healthy tissue is as low as possible to prevent damage. Both can be achieved with appropriate positioning of the electrodes and appropriate amplitude of electric pulses. Methods. We used 3D finite element numerical models and a genetic optimization algorithm to determine the optimum electrode configuration and optimum amplitude of electric pulses for treatment of three subcutaneous tumor models of different shapes and sizes and a realistic brain tumor model acquired from medical images. Results. In all four tumor cases, parallel needle electrode arrays were a better choice than hexagonal needle electrode arrays, since their utilization required less electric current and caused less healthy tissue damage. In addition, regardless of tumor geometry or needle electrode configuration, the optimum depth of electrode insertion was in all cases deeper than the deepest part of the tumor. Conclusions. Our optimization algorithm was able to determine the best electrode configuration in all four presented models and with further improvement it could be a useful tool in clinical electrochemotherapy treatment planning.
Publication status:Published
Publication version:Version of Record
Publication date:01.01.2008
Publisher:Association of Radiology and Oncology
Year of publishing:2008
Number of pages:str. 93-101
Numbering:Letn. 42, št. 2
Source:Ljubljana
PID:20.500.12556/DiRROS-18352 New window
UDC:616-006
ISSN on article:1318-2099
COBISS.SI-ID:24489945 New window
Copyright:by Authors
Note:BSDOCID139559;
Publication date in DiRROS:08.03.2024
Views:95
Downloads:30
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
  
Share:Bookmark and Share


Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Record is a part of a journal

Title:Radiology and oncology
Shortened title:Radiol. oncol.
Publisher:Slovenian Medical Society - Section of Radiology, Croatian Medical Association - Croatian Society of Radiology
ISSN:1318-2099
COBISS.SI-ID:32649472 New window

Secondary language

Language:Slovenian
Title:Optimizacija položaja elektrod in amplitude električnih pulzov v elektrokemoterapija


Back