Title:Cell electropermeabilization to small molecules in vitro : control by pulse parameters
Authors:ID Maček Lebar, Alenka (Author)
ID Miklavčič, Damijan (Author)
Files:.pdf PDF - Presentation file, download (508,35 KB)
MD5: 763CA6196E835C092FFA64E374B5B186
 
Language:English
Typology:1.01 - Original Scientific Article
Organization:Logo OI - Institute of Oncology
Abstract:A systematic study concerning the role of the different electric field parameters (pulse number, duration and amplitude) on electropermeabilization of DC3F cells to small molecules (propidium iodide) and on cell viability is presented. Cell permeabilization and viability dependence on the pulse amplitude was determined by twenty different sets of electrical parameters. The number of pulses varied between 1 and 64 and pulse duration between 20 micros and 1 ms. The most important parameter was the pulse amplitude because at triggered the electropermeabilization process and the process of cell death. Either in the case of electropermeabilization as well as in the case ofcell viability experiments, the parameter Uso (the pulse amplitude leading to permeabilization or to the death of 50% of cell population) was not changedif the set of electrical parameters consisted of more than 16 pulses. This was independent of the pulse duration. The efficiency of permeabilizationwas enhanced by using of longer pulses. Such a systematic study of the influence of different electric field parameters on electropermeabilization and cell viability may serve as a base for optimization of the electropermeabilization conditions for different applications.
Publication status:Published
Publication version:Version of Record
Publication date:01.09.2001
Publisher:Slovenian Medical Association - Slovenian Association of Radiology, Nuclear Medicine Society, Slovenian Society far Radiotherapy and Oncology, and Slovenian Cancer Society
Year of publishing:2001
Number of pages:str. 193-202
Numbering:Letn. 35, št. 3
Source:Ljubljana
PID:20.500.12556/DiRROS-17999 New window
UDC:616-006
ISSN on article:1318-2099
COBISS.SI-ID:13704921 New window
Copyright:by Authors
Note:BSDOCID83536;
Publication date in DiRROS:25.01.2024
Views:205
Downloads:41
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
  
Share:Bookmark and Share


Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Record is a part of a journal

Title:Radiology and oncology
Shortened title:Radiol. oncol.
Publisher:Slovenian Medical Society - Section of Radiology, Croatian Medical Association - Croatian Society of Radiology
ISSN:1318-2099
COBISS.SI-ID:32649472 New window

Secondary language

Language:Slovenian
Title:Elektropermeabilizacija celic z majhnimi molekulami in vitro : vpliv električnih parametrov
Abstract:V članku predstavljamo sistematično študijo vloge različnih električnih parametrov (število, trajanje in amplituda električnih pulzov) v procesu elektropermeabilizacije celic DC3F za majhne molekule in vpliva teh parametrovna preživetje celic. Permeabilizacijo celic in njihovo preživetje smo določili za dvajset različnih naborov električnih pulzov. Število električnih pulzov smo spreminjali od 1 do 64, njihovo trajanje pa med 20 mikros in 1 ms. Najpomembnejši električni parameter je amplituda električnih pulzov, saj sproži proces elektropermeabilizacije in proces umiranja celic. Tako v primeru elektropermeabilizacije celic kot tudi ob študiju celičnega preživetja smo ugotovili, da se parameter U5o (tj. amplituda električnih pulzov pri kateri je permeabiliziranih (ali mrtvih) 50% celic v populaciji) nespremeni, če uporabljeni vlak električnih pulzov sestavlja več kot 16 električnih pulzov. Ugotovitev je neodvisna od njihovega trajanja. Perrneabilizacija je učinkovitejša, če uporabimo daljše električne pulze. Takosistematično študijo vpliva električnih parametrov na elektropermeabilizacijo in preživetje celic lahko uparabimo kot osnovo za optimizacijo elektropermeabilizacijskih pogojev pri različnih aplikacijah elektropermeabilizacije.


Back