Digital repository of Slovenian research organisations

Show document
A+ | A- | Help | SLO | ENG

Title:Hydrocolonic sonography in the detection of large bowel disease
Authors:ID Vidmar, Dubravka (Author)
Files:.pdf PDF - Presentation file, download (598,29 KB)
MD5: 04E54ABA0E2B90521035CCB369793C38
 
Language:English
Typology:1.01 - Original Scientific Article
Organization:Logo OI - Institute of Oncology
Abstract:Background. The presence of fluid in the bowel lumen improves the sonographic visualisation of the gastrointestinal tract, thus permitting earlier and more accurate detection of pathological changes. Hydrocolonic sonographic (HS) is amethod of examination the colon after it has been cleaned and filled with water. Patients and methods. We have evaluated the method in a group of 56 patients by comparing its results with the findings of colonoscopy, double-contrast barium enema or surgery. Results. HS had an overall accuracy of 86%, a sensitivity of 81%, a specificity of 92%, a positive predictive value of 91% and a negative predictive value of 82%. Conclusions. The technique is not suitable for examination the rectum, but apart from that it is comparable in usefulness to double-contrast barium enema. The main limitation of HS is that it requires a lot of experience and skill on the partof the sonologist, which affects its acceptability for diagnostic evaluation of the colon.
Publication status:Published
Publication version:Version of Record
Publication date:01.01.2000
Publisher:Slovenian Medical Association - Slovenian Association of Radiology, Nuclear Medicine Society, Slovenian Society far Radiotherapy and Oncology, and Slovenian Cancer Society
Year of publishing:2000
Number of pages:str. 165-173
Numbering:Letn. 34, št. 2
Source:Ljubljana
PID:20.500.12556/DiRROS-17955 New window
UDC:616.3
ISSN on article:1318-2099
COBISS.SI-ID:11711705 New window
Copyright:by Authors
Note:BSDOCID53028;
Publication date in DiRROS:24.01.2024
Views:213
Downloads:39
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
  
Share:Bookmark and Share


Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Record is a part of a journal

Title:Radiology and oncology
Shortened title:Radiol. oncol.
Publisher:Slovenian Medical Society - Section of Radiology, Croatian Medical Association - Croatian Society of Radiology
ISSN:1318-2099
COBISS.SI-ID:32649472 New window

Secondary language

Language:Slovenian
Title:[Hidrokolonsonografija v odkrivanju bolezni širokega črevesa]
Abstract:Izhodišča. Tekočina v lumnu izboljša preglednost prebavne cevi do te mere, da se patološke spremembe odkrivajo prej in bolj natančno. Diagnostično metodo zaširoko črevo, ki se po predhodnem izčiščenju retrogradno napolni z vodo, imenujemo hidrokolonsonografija (HS). Bolniki in metode. Uspešnost metode smo testirali v skupini 56 bolnikov z primerjavo izvidov HS in kolonoskopije (KS) ali irigografije ali operativnim izvidom. Rezultati. Celokupna točnost je bila86%, senzitivnost 81%, specifičnost 92%, pozitivna napovedna vrednost (PPV) 91% in negativna napovedna vrednost (NPV) 82%. Zaključki. HS je po uspešnosti primerljiva z irigografijo razen za prikaz rektuma. Omejitev preiskave je v tem, da je zahtevna za preiskovalca, kar vpliva na njeno sprejemljivost v diagnostiki širokega črevesa.


Back