Digital repository of Slovenian research organisations

Search the repository
A+ | A- | Help | SLO | ENG

Query: search in
search in
search in
search in

Options:
  Reset


Query: "author" (Črtomir Donik) .

1 - 10 / 23
First pagePrevious page123Next pageLast page
1.
Susceptibility of X17CrNi16-2 martensitic stainless steel to hydrogen embrittlement after conventional and deep cryogenic heat treatment
Mirjam Bajt Leban, Bojan Zajec, Bojan Podgornik, Črtomir Donik, Patricia Jovičević Klug, Miha Hren, Andraž Legat, 2024, original scientific article

Abstract: A low carbon/ high chromium martensitic stainless steel, X17CrNi16-2, was heat treated using two different hardening and tempering regimes (1050 ◦ C/480 ◦ C or 980 ◦C/600 ◦C) — promoting either a high strength or high toughness state, respectively and further combined with deep cryogenic treatment (DCT) at 196 ◦C for 24 h. Over recent years DCT has been recognized as a promising technique to improve the properties of steel, predominantly with respect to its tensile strength, toughness and wear resistance. The influence of DCT on the hydrogen embrittlement resistance of martensitic stainless steel has not yet, however, been reported. A slow strain rate tensile test (SSRT) with simultaneous cathodic hydrogen charging was selected as the method to assess potential susceptibility to hydrogen embrittlement (HE). Relatively low-intensity hydrogen charging, utilizing a constant current density of 0.1 mA/cm2, in a non-corrosive, slightly alkaline buffer solution, led to a clear reduction in the ultimate tensile stress. This reduction, and therefore the HE susceptibility, was more pronounced in the steel with a higher strength (i.e. that subject to the 1050 ◦C/ 480 ◦C heat treatment condition). Furthermore, DCT did not appear to have any impact on the steel’s mechanical properties in the presence of hydrogen. Fractographic analysis showed clear evidence of HE in the hydrogen-charged specimens. This paper presents results of the SSRT tests and further fractography results, and discusses the impact of conventional and deep cryogenic treatment on HE susceptibility.
Keywords: martensitic stainless steel, deep cryogenic treatment, hydrogen embrittlement, slow strain rate tensile test
Published in DiRROS: 23.05.2024; Views: 75; Downloads: 76
.pdf Full text (17,73 MB)
This document has many files! More...

2.
3.
4.
5.
6.
Bioresorbability dependence on microstructure of additivelly- manufactured and conventionally-produced Fe-Mn alloys
Matjaž Godec, Jakob Kraner, Danijela Anica Skobir Balantič, Irena Paulin, Damjana Drobne, Veno Kononenko, Aleksandra Kocijan, Paul J. McGuiness, Črtomir Donik, 2024, complete scientific database of research data

Abstract: The dataset supports the results shown in the tables and figures in the article entitled “Bioresorbability Dependence on Microstructure of Additivelly-Manufactured and Conventionally-Produced Fe-Mn Alloys” (doi.org/10.1016/j.jmrt.2024.04.097). It contains measurements of corrosion resistance of Fe-Mn samples, phase analysis of samples A, B and C, surface and depth profiling XPS, EDS measurements of a cross-section of Fe-Mn powder particles and viability measurements results.
Keywords: Fe-Mn alloy, laser powder bed fusion, bioresorbable, microstructure, corrosion behaviour, biocompatibility
Published in DiRROS: 12.04.2024; Views: 254; Downloads: 116
.xlsx Full text (2,55 MB)
This document has many files! More...

7.
8.
9.
10.
Search done in 0.32 sec.
Back to top