| Title: | A coupled multi-electrode array sensor for monitoring galvanic corrosion between copper and steel |
|---|
| Authors: | ID Kregar, Klara (Author) ID Hren, Miha (Author) ID Nagode, Aleš (Author) ID Kosec, Tadeja (Corresponding author) |
| Files: | URL - Source URL, visit https://iopscience.iop.org/article/10.1149/1945-7111/ae89ec
PDF - Presentation file, download (5,17 MB) MD5: 85D46576E51336530483C07A7ADE6DDD
URL - Research data, visit http://hdl.handle.net/20.500. 12556/DiRROS-30541
|
|---|
| Language: | English |
|---|
| Typology: | 1.01 - Original Scientific Article |
|---|
| Organization: | ZAG - Slovenian National Building and Civil Engineering Institute
|
|---|
| Abstract: | The advanced coupled multi-electrode array (CMEA) technique provides spatiotemporal insights into electrochemical processes. This study used the CMEA technique to monitor the distribution of anodic and cathodic activity during galvanic interactions between copper and steel. An important parameter influencing the intensity of galvanic corrosion is the anode-to-cathode area ratio, which was also investigated. After exposure, corrosion products were analyzed using microscopic and spectroscopic techniques, and the extent of actual corrosion damage was evaluated using µ-CT. In the CMEA sensor with a Cu:CS ratio of 24:1, the corrosion rate of the CS electrode was estimated at 0.86 mm year−1 . For the area ratio of Cu:CS 22:3, a lower corrosion rate of 0.56 mm year−1 was observed for the CS electrodes. The influence of the reduction process on copper electrodes and the intensity of galvanic corrosion is demonstrated. The main corrosion products on the CS electrodes were goethite, lepidocrocite, and akaganeite, indicating a corrosion process involving oxygen. The copper electrodes acted as cathodes, but some individual Cu electrodes also exhibited anodic activity. This suggests simultaneous anodic and cathodic activity, and the anodic activity was confirmed by Raman spectroscopy, which detected the presence of Cu2O. Cu2S was also detected, indicating corrosion processes involving bisulfide ions. |
|---|
| Keywords: | carbon steel, copper, galvanic corrosion, coupled multi-electrode arrays (CMEA), oxic environment |
|---|
| Publication status: | Published |
|---|
| Publication version: | Version of Record |
|---|
| Publication date: | 27.07.2026 |
|---|
| Publisher: | Electrochemical Society |
|---|
| Year of publishing: | 2026 |
|---|
| Number of pages: | str. [1-13] |
|---|
| Numbering: | Vol. 173, no. 14, [article no.] 147503 |
|---|
| PID: | 20.500.12556/DiRROS-31392  |
|---|
| UDC: | 544.5/.6 |
|---|
| ISSN on article: | 1945-7111 |
|---|
| DOI: | 10.1149/1945-7111/ae89ec  |
|---|
| COBISS.SI-ID: | 286375939  |
|---|
| Copyright: | © 2026 The Author(s) |
|---|
| Note: |
|
|---|
| Publication date in DiRROS: | 31.07.2026 |
|---|
| Views: | 16 |
|---|
| Downloads: | 24 |
|---|
| Metadata: |  |
|---|
|
:
|
Copy citation |
|---|
| | | | Share: |  |
|---|
Hover the mouse pointer over a document title to show the abstract or click
on the title to get all document metadata. |