| Title: | Ultrasound-guided thread versus ultrasound-guided needle release of the A1 pulley: a cadaveric study : a systematic review and meta-analysis |
|---|
| Authors: | ID Jengojan, Suren Armeni (Author) ID Sorgo, Philipp (Author) ID Streicher, Johannes (Author) ID Snoj, Žiga (Author) ID Kasprian, Gregor (Author) ID Gruber, Gerlinde (Author) ID Bodner, Gerd (Author) |
| Files: | PDF - Presentation file, download (1,29 MB) MD5: C4468168B6DE643319E39AC4F77D58E3
URL - Source URL, visit https://link.springer.com/article/10.1007/s11547-024-01875-y
|
|---|
| Language: | English |
|---|
| Typology: | 1.01 - Original Scientific Article |
|---|
| Organization: | UKC LJ - Ljubljana University Medical Centre
|
|---|
| Abstract: | Purpose To assess and compare two ultrasound-guided, minimally invasive procedures to release the A1-pulley (needle release and thread release) regarding efcacy and safety in an anatomical specimen model. Materials and methods Twenty-one ultrasound-guided needle releases and 20 ultrasound-guided thread releases were performed on digits of Thiel-embalmed anatomical specimens. A scoring system was developed to assess ultrasound visibility, intervention outcome (incomplete, almost complete, or full transection of the A1 pulley), and injury to adjacent structures (neurovascular structures, tendons, A2 pulley). Statistical analysis was performed to compare the score of the two groups (group 1: needle release,group 2: thread release). A P-value of≤0.05 was considered signifcant. Results Needle release was completely successful in 15 cases (71.5%), almost complete release was achieved in four cases (19%), and incomplete transection occurred in two cases (9.5%). Thread release was completely successful in 17 cases (85%), and almost complete transection was observed in the remaining three cases (15%). In both procedures no neurovascular structures were harmed. Slight injury of fexor tendons occurred in two cases (9.5%) in needle release and in fve cases (25%) in thread release. There were no signifcant statistical diferences between the groups regarding ultrasound visibility, intervention safety and outcome, (P>0.05). Conclusion Ultrasound-guided needle release and ultrasound-guided thread release have similar success of release, both being efective and safe techniques for the release of the A1 pulley |
|---|
| Keywords: | ultrasonography, fingers, decompression, ligaments, cadavers |
|---|
| Publication status: | Published |
|---|
| Publication version: | Version of Record |
|---|
| Year of publishing: | 2024 |
|---|
| Number of pages: | str. 1513–1521 |
|---|
| Numbering: | Vol. 129 |
|---|
| PID: | 20.500.12556/DiRROS-30731  |
|---|
| UDC: | 616-07 |
|---|
| ISSN on article: | 1826-6983 |
|---|
| DOI: | 10.1007/s11547-024-01875-y  |
|---|
| COBISS.SI-ID: | 205902339  |
|---|
| Note: | Nasl. z nasl. zaslona;
Opis vira z dne 30. 8. 2024;
|
|---|
| Publication date in DiRROS: | 01.07.2026 |
|---|
| Views: | 169 |
|---|
| Downloads: | 108 |
|---|
| Metadata: |  |
|---|
|
:
|
Copy citation |
|---|
| | | | Share: |  |
|---|
Hover the mouse pointer over a document title to show the abstract or click
on the title to get all document metadata. |