Digital repository of Slovenian research organisations

Show document
A+ | A- | Help | SLO | ENG

Title:Long-term outcome of multilayer flow modulator in aortic aneurysms
Authors:ID Pintarić, Karlo (Author)
ID Boltežar, Lučka (Author)
ID Umek, Nejc (Author)
ID Kuhelj, Dimitrij (Author)
Files:.pdf PDF - Presentation file, download (605,81 KB)
MD5: DC5F0492747988254179D4CF527C56D4
 
URL URL - Source URL, visit https://sciendo.com/article/10.2478/raon-2024-0021?tab=abstract
 
Language:English
Typology:1.01 - Original Scientific Article
Organization:Logo DRO - Association of Radiology and Oncology
Abstract:ckground. This retrospective study investigated the efficacy of endovascular treatment with multilayer flow modu-lators (MFMs) for treating aortic aneurysms in high-risk patients unsuitable for conventional treatments.Patients and methods. Conducted from 2011 to 2019 at a single center, this retrospective observational study in-cluded 17 patients who underwent endovascular treatment with MFMs. These patients were selected based on theirunsuitability for traditional surgical or endovascular procedures. The study involved meticulous pre-procedural plan-ning, precise implantation of MFMs, and follow-up using CT angiography. The primary focus was on volumetric andflow volume changes in aneurysms, along with traditional diameter measurements. Moreover, the technical successand post-procedural complications were also registered.Results. The technical success rate was 100%, and 30-day procedural complication rate was 17.6%. Post-treatmentassessments revealed that 11 out of 17 patients showed a decrease in flow volume within the aneurysm sac, indicativeof a favorable hemodynamic response. The median decrease in flow volume was 12 ml, with a median relative de-crease of 8%. However, there was no consistent reduction in aneurysm size; most aneurysms demonstrated a medianincrease in volume for 46 ml and median increase in diameter for 18 mm.Conclusions. While MFMs offer a potential alternative for high-risk aortic aneurysm patients, their effectiveness in pre-venting aneurysm expansion is limited. The results suggest that MFMs can provide a stable hemodynamic environmentbut do not reliably reduce aneurysm size. This underscores the need for ongoing vigilance and long-term monitoringin patients treated with this technology
Keywords:multilayer flow modulator, aortic aneurism, long-term follow up, volumetric measurements
Publication status:Published
Publication version:Version of Record
Publication date:01.06.2024
Publisher:Association of Radiology and Oncology
Year of publishing:2024
Number of pages:str. 206-213 , V
Numbering:Vol. 58, no. 2
Source:Ljubljana
PID:20.500.12556/DiRROS-30454 New window
UDC:616-006
ISSN on article:1318-2099
DOI:10.2478/raon-2024-0021 New window
COBISS.SI-ID:195722755 New window
Note:Soavtorji: Lucka Boltezar, Nejc Umek, Dimitrij Kuhelj;
Publication date in DiRROS:26.06.2026
Views:167
Downloads:128
Metadata:XML DC-XML DC-RDF
:
Copy citation
  
Share:Bookmark and Share


Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Record is a part of a journal

Title:Radiology and oncology
Shortened title:Radiol. oncol.
Publisher:Slovenian Medical Society - Section of Radiology, Croatian Medical Association - Croatian Society of Radiology
ISSN:1318-2099
COBISS.SI-ID:32649472 New window

Licences

License:CC BY 4.0, Creative Commons Attribution 4.0 International
Link:http://creativecommons.org/licenses/by/4.0/
Description:This is the standard Creative Commons license that gives others maximum freedom to do what they want with the work as long as they credit the author.

Secondary language

Language:Slovenian
Title:Dolgoročna učinkovitost večplastnih modulatorjev pretoka za zdravljenje aortnih anevrizem
Keywords:večplastni modulator pretoka, anevrizma aorte, dolgoročno spremljanje, prostorninske meritve


Back