| Title: | Subdiaphragmatic activity-related artifacts in myocardial perfusion scintigraphy |
|---|
| Authors: | ID Štrok, Anja (Author) ID Gužič-Salobir, Barbara (Author) ID Štalc, Monika (Author) ID Zaletel, Katja (Author) |
| Files: | URL - Source URL, visit https://www.radioloncol.com/index.php/ro/article/view/4409/5244
PDF - Presentation file, download (775,41 KB) MD5: D35A0838CFF18077252CABA788FF75BE
|
|---|
| Language: | English |
|---|
| Typology: | 1.02 - Review Article |
|---|
| Organization: | DRO - Association of Radiology and Oncology
|
|---|
| Abstract: | Background. Myocardial perfusion imaging (MPI) with single photon emission computed tomography is an established non-invasive technique for assessing myocardial ischemia. This method involves the intravenous administration of a radiopharmaceutical that accumulates in the heart muscle proportional to regional blood flow. However, image quality and diagnostic accuracy can be compromised by various technical and patient-related factors, including high non-specific radiopharmaceutical uptake in abdominal organs such as the stomach, intestines, liver, and gallbladder, leading to subdiaphragmatic artifacts. These artifacts are particularly problematic for evaluating inferior wall perfusion and often necessitate repeated imaging, which decreases gamma camera availability and prolongs imaging times. Conclusions. Despite numerous investigated techniques to reduce interfering gastrointestinal activity, results have been inconsistent, and current MPI guidelines provide scant information on effective procedures to mitigate this issue. Based on our experience, some possible approaches to reducing artifacts include choosing stress testing with an exercise stress test, when possible, late imaging, fluid intake, and consuming carbonated water immediately before imaging |
|---|
| Keywords: | myocardial perfusion imaging, artifacts, subdiaphragmatic activity, single photon emission computed tomography, intervention |
|---|
| Publication status: | Published |
|---|
| Publication version: | Version of Record |
|---|
| Publication date: | 01.09.2024 |
|---|
| Publisher: | Association of Radiology and Oncology |
|---|
| Year of publishing: | 2024 |
|---|
| Number of pages: | str. 313-319, I |
|---|
| Numbering: | Vol. 58, no. 3 |
|---|
| Source: | Ljubljana |
|---|
| PID: | 20.500.12556/DiRROS-30433  |
|---|
| UDC: | 61 |
|---|
| ISSN on article: | 1318-2099 |
|---|
| DOI: | 10.2478/raon-2024-0053  |
|---|
| COBISS.SI-ID: | 210650883  |
|---|
| Note: | Soavtorji: Barbara Guzic Salobir, Monika Stalc, Katja Zaletel;
|
|---|
| Publication date in DiRROS: | 24.06.2026 |
|---|
| Views: | 164 |
|---|
| Downloads: | 105 |
|---|
| Metadata: |  |
|---|
|
:
|
Copy citation |
|---|
| | | | Share: |  |
|---|
Hover the mouse pointer over a document title to show the abstract or click
on the title to get all document metadata. |