Digital repository of Slovenian research organisations

Show document
A+ | A- | Help | SLO | ENG

Title:Transcatheter aortic valve implantation in the first 500 patients : a single-center retrospective study
Authors:ID Noč, Marko (Author)
ID Pleskovič, Aleš (Author)
ID Rojko, Maja (Author)
ID Černič Šuligoj, Nataša (Author)
ID Cvetičanin, Branko (Author)
ID Špan, Matjaž (Author)
ID Šušak, Stamenko (Author)
ID Stopar, Rok (Author)
ID Petrovič, Danijel (Author)
ID Noč, Naomi Ana (Author)
ID Bošnjak, Ana (Author)
ID Danojević, Nenad (Author)
ID Djordjevic, Miladin (Author)
ID Zorc, Marjeta (Author), et al.
Files:.pdf PDF - Presentation file, download (304,08 KB)
MD5: 90BB62DCA8ED748D5A5568A48884E6C4
 
URL URL - Source URL, visit https://www.cmj.hr/2024/65/5/39492452.htm
 
Language:English
Typology:1.01 - Original Scientific Article
Organization:Logo UKC LJ - Ljubljana University Medical Centre
Abstract:Aim To determine the procedural characteristics, results, and long-term outcomes of the first 500 consecutive patients undergoing transcatheter aortic valve implantation (TAVI) at the MC Medicor International Center for Cardiovascular Diseases Izola (Slovenia). Methods Data were collected from the institutional registry. The date of death was obtained from the National BIRPIS system by using the patient’s health insurance card number. The difference in 30-day mortality was assessed between two consecutive cohorts of 250 patients, patients who received self-expandable (SEV) and those with balloon-expandable (BEV) valves, and between patients ≤80 and >80 years old. Results Between December 2016 and September 2023, 500 patients (80 ± 6 years, 52% men, EuroScore II, 4.09 ± 4.11), including 3.2% with degenerated surgical prosthesis, underwent TAVI. After predilatation (57%), SEV was implanted in 87.5% and BEV in 12.5% of the patients. The mean postprocedural gradient was 10 ± 4 mm Hg, with more than moderate regurgitation in 0.4%. Emergency cardiac/vascular surgery was performed in 1.4%, and stroke occurred in 0.8%. The new permanent pacemaker (PPM) rate decreased from 19% to 7% (P < 0.001) in the second cohort, and the mean postprocedural transaortic gradient was significantly lower after SEV compared with BEV (9 ± 4 vs 13 ± 4 mm Hg; P < 0.001). There was no difference in 30-day mortality between the first and second cohort of 250 patients (1.2% vs 1.2%; P = 1.000), cohorts of 50 patients from number 0 to 500 (0% vs 2.0%; P = 0.391), SEV and BEV groups (0.9% vs 1.6%; P = 0.487), and patients ≤80 and >80 years old (2.0% vs 0.4%; P = 0.119). Conclusion TAVI results in our study are comparable with international standards. PPM rate decreased over time, and postprocedural gradient was lower after SEV. Learning curve, type of valve, and patient age did not affect 30-day mortality.
Keywords:aortic valve, transcatheter implantation, retrospective study
Publication status:Published
Publication version:Version of Record
Year of publishing:2024
Number of pages:str. 424-430
Numbering:Vol. 65, no. 5
PID:20.500.12556/DiRROS-29792 New window
UDC:616.1
ISSN on article:0353-9504
DOI:10.3325/cmj.2024.65.424 New window
COBISS.SI-ID:215682819 New window
Publication date in DiRROS:05.06.2026
Views:50
Downloads:33
Metadata:XML DC-XML DC-RDF
:
Copy citation
  
Share:Bookmark and Share


Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Record is a part of a journal

Title:Croatian medical journal
Shortened title:Croat. med. j.
Publisher:University of Zagreb Medical School
ISSN:0353-9504
COBISS.SI-ID:33135360 New window

Licences

License:CC BY-NC-ND 4.0, Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
Link:http://creativecommons.org/licenses/by-nc-nd/4.0/
Description:The most restrictive Creative Commons license. This only allows people to download and share the work for no commercial gain and for no other purposes.

Secondary language

Language:Slovenian
Keywords:aortna zaklopka, transkateterska implantacija, retrospektivna študija


Back