Digital repository of Slovenian research organisations

Show document
A+ | A- | Help | SLO | ENG

Title:Two-year outcomes of tissue-level and bone-level two-piece zirconia implants : a case series
Authors:ID Žarković Gjurin, Sonja (Author)
ID Povšič, Katja (Author)
ID Kobe, Tom (Author)
ID Žužek, Borut (Author)
ID Gašperšič, Rok (Author)
ID Oblak, Čedomir (Author)
Files:.pdf PDF - Presentation file, download (1,42 MB)
MD5: D42988EF7AF523CA902FED5D2E543E5C
 
URL URL - Source URL, visit https://www.mdpi.com/2673-6373/6/1/1
 
Language:English
Typology:1.01 - Original Scientific Article
Organization:Logo UKC LJ - Ljubljana University Medical Centre
Abstract:Background/objectives: Zirconia dental implants are increasingly recognised as an alternative to titanium implants due to their biocompatibility and aesthetics. Initially developed as one-piece systems, zirconia implants have evolved into two-piece designs with different platform levels; however, comparative data on their primary and secondary stability– particularly as assessed by resonance frequency analysis (RFA)—and marginal bone dynamics remain limited. This case series aimed to evaluate the implant stability and marginal bone changes of two-piece zirconia implants with bone-level (BL) and tissue-level (TL) platforms in patients missing maxillary premolars. Methods: Thirteen zirconia implants (n = 13; 7 BL, 6 TL; Z5-TL/Z5-BL, Z-Systems, Switzerland) were placed in 11 patients with healed ridges. The implant stability quotient (ISQ) was measured immediately after insertion and before prosthetic loading. Lithium disilicate crowns were cemented after four months, and follow-ups were conducted for an average of 35 months (SD = 12). Results: Initial ISQ values ranged from 73 to 79, increasing to 76–84 at 3–4 months, indicating high implant stability for both BL and TL implants. The extent of marginal bone loss (MBL) after two years was greater around BL implants (mean 0.46 mm) compared to TL implants (mean 0.2 mm), although probing depths and bleeding on probing remained minimal in both groups, with only one TL implant showing gingival recession. Conclusions: Over a short observation period, two-piece zirconia implants with tissue-level platforms appeared to demonstrate superior marginal tissue stability. Further, larger-scale controlled studies are required to confirm these preliminary observations.
Keywords:zirconia implants, ceramic, two-piece, bone-level, tissue-level, implant stability, ISQ
Publication status:Published
Publication version:Version of Record
Year of publishing:2026
Number of pages:str. 1-13
Numbering:Vol. 6, no. 1
PID:20.500.12556/DiRROS-28822 New window
UDC:616.31
ISSN on article:2673-6373
DOI:10.3390/oral6010001 New window
COBISS.SI-ID:264750083 New window
Note:Nasl. z nasl. zaslona; Opis vira z dne 15. 1. 2026;
Publication date in DiRROS:08.04.2026
Views:271
Downloads:217
Metadata:XML DC-XML DC-RDF
:
Copy citation
  
Share:Bookmark and Share


Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Record is a part of a journal

Title:Oral
Shortened title:Oral
ISSN:2673-6373
COBISS.SI-ID:80648451 New window

Licences

License:CC BY 4.0, Creative Commons Attribution 4.0 International
Link:http://creativecommons.org/licenses/by/4.0/
Description:This is the standard Creative Commons license that gives others maximum freedom to do what they want with the work as long as they credit the author.

Secondary language

Language:Slovenian
Keywords:cirkonijevi vsadki, keramika, dvodelni, na ravni kosti, na ravni tkiva, stabilnost vsadka


Back