Digital repository of Slovenian research organisations

Show document
A+ | A- | Help | SLO | ENG

Title:Combined use of chlorophyll a and phycocyanin fluorescence sensors for quantification and differentiation of phytoplankton : a useful approach for small surface water bodies
Authors:ID Rozina, Tinkara (Author)
ID Eleršek, Tina (Author)
ID Zupančič Justin, Maja (Author)
ID Meglič, Andrej (Author)
Files:.pdf PDF - Presentation file, download (699,64 KB)
MD5: 7F2FFA24D650A701AB6208ECF6ADD301
 
URL URL - Source URL, visit https://doi.org/10.14720/abs.61.2.15891
 
Language:English
Typology:1.01 - Original Scientific Article
Organization:Logo NIB - National Institute of Biology
Abstract:Sensors based on in vivo measurements of photosynthetic pigments fluorescence enable real-time phytoplankton monitoring with high spatial and temporal resolution. A combination of chlorophyll a (CHL) and phycocyanin (PC) fluorescence sensors was used for phytoplankton quantification and differentiation in two small water bodies, Koseze Pond and pond in Hotinja vas. The high correlation of CHL and PC fluorescence signals with biovolume was confirmed during the two-year monitoring in anatural pond environment in spite of a seasonal succession of the phytoplankton. Additionally, disturbances of the sensors were investigated. Water bodies containing predominantly algae yielded false positive signals of the PC sensor, which reached up to 1% of the intensity of the CHL signal. Similarly, underestimated counts of cyanobacteria measured with CHL fluorescence sensor can be adjusted using PC fluorescence sensor.
Keywords:small water bodies, algae, cyanobacteria, fluorescence sensors, biovolume
Publication status:Published
Publication version:Version of Record
Publication date:01.12.2018
Year of publishing:2018
Number of pages:str. 29-37
Numbering:Vol. 61, št. 2
PID:20.500.12556/DiRROS-19990 New window
UDC:582.261/.279
ISSN on article:1408-3671
COBISS.SI-ID:4937551 New window
Note:Besedilo v angl.;
Publication date in DiRROS:01.08.2024
Views:17
Downloads:13
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
  
Share:Bookmark and Share


Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Record is a part of a journal

Title:Acta biologica slovenica : ABS
Shortened title:Acta biol. slov.
Publisher:Društvo biologov Slovenije
ISSN:1408-3671
COBISS.SI-ID:68526592 New window

Licences

License:CC BY-SA 4.0, Creative Commons Attribution-ShareAlike 4.0 International
Link:http://creativecommons.org/licenses/by-sa/4.0/
Description:This Creative Commons license is very similar to the regular Attribution license, but requires the release of all derivative works under this same license.

Secondary language

Language:Slovenian
Title:Kombinirana uporaba klorofilnega in fikocianinskega senzorja fluorescence za kvantifikacijo in kvalifikacijo fitoplanktona : uporaba v majhnih vodnih telesih
Abstract:Senzorji za merjenje in vivo fluorescence fotosintetskih pigmentov omogočajo meritve fitoplanktona z visoko časovno in prostorsko ločljivostjo. Kombinacijo klorofilnega (CHL) in fikocianinskega (PC) senzorja smo uporabili za kvantitativno in kvalitativno spremljanje fitoplanktona v dveh majhnih vodnih telesih, Koseškem bajerju in ribniku v Hotinji vasi. Kljub spreminjanju vrstne sestave je ostala korelacija med signalom CHL senzorja in biovolumnom visoka. Opredelili smo tudi napake senzorjev. V primeru vodnih teles z visoko koncentracijo zelenih alg je PC senzor dajal lažen pozitiven signal v velikosti 1 % signal CHL senzorja. S kombinacijo obeh senzorjev je mogoče odpraviti tudi podcenitev koncentracije cianobakterij, do katere pride ob uporabi le CHL senzorja.
Keywords:mala vodna telesa, alge, cianobakterije, senzorji fluorescence, biovolumen


Back