Title:Uncertainties in target volume delineation in radiotherapy : are they relevant and what can we do about them?
Authors:ID Šegedin, Barbara (Author)
ID Petrič, Primož (Author)
Files:URL URL - Source URL, visit https://www.degruyter.com/downloadpdf/j/raon.2016.50.issue-3/raon-2016-0023/raon-2016-0023.xml
 
.pdf PDF - Presentation file, download (904,32 KB)
MD5: 8832F1D22DDB6F06E217DB56EA1F9E41
 
Language:English
Typology:1.01 - Original Scientific Article
Organization:Logo OI - Institute of Oncology
Abstract:Modern radiotherapy techniques enable delivery of high doses to the target volume without escalating dose to organs at risk, offering the possibility of better local control while preserving good quality of life. Uncertainties in target volume delineation have been demonstrated for most tumour sites, and various studies indicate that inconsistencies in target volume delineation may be larger than errors in all other steps of the treatment planning and delivery process. The aim of this paper is to summarize the degree of delineation uncertainties for different tumour sites reported in the literature and review the effect of strategies to minimize them. Conclusions. Our review confirmed that interobserver variability in target volume contouring represents the largest uncertainty in the process for most tumour sites, potentially resulting in a systematic error in dose delivery, which could influence local control in individual patients. For most tumour sites the optimal combination of imaging modalities for target delineation still needs to be determined. Strict use of delineation guidelines and protocols is advisable both in every day clinical practice and in clinical studies to diminish interobserver variability. Continuing medical education of radiation oncologists cannot be overemphasized, intensive formal training on interpretation of sectional imaging should be included in the program for radiation oncology residents.
Keywords:target volume, interobserver variability, delineation uncertainties, imaging
Publication status:Published
Publication version:Version of Record
Publication date:01.09.2016
Publisher:Association of Radiology and Oncology
Year of publishing:2016
Number of pages:str. 254-262, I
Numbering:Vol. 50, no. 3
Source:Ljubljana
PID:20.500.12556/DiRROS-18868 New window
UDC:615.849
ISSN on article:1318-2099
DOI:10.1515/raon-2016-0023 New window
COBISS.SI-ID:2488955 New window
Copyright:by Authors
Publication date in DiRROS:30.04.2024
Views:773
Downloads:559
Metadata:XML DC-XML DC-RDF
:
Copy citation
  
Share:Bookmark and Share


Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Record is a part of a journal

Title:Radiology and oncology
Shortened title:Radiol. oncol.
Publisher:Slovenian Medical Society - Section of Radiology, Croatian Medical Association - Croatian Society of Radiology
ISSN:1318-2099
COBISS.SI-ID:32649472 New window

Secondary language

Language:Slovenian
Keywords:radioterapija, obsevanje, tarčni volumni, vrisovanje, razlike, zmanjševanje neujemanja


Back