Title:Model uncertainty in a parametric fire curve approach : a stochastic correction factor for the compartment fire load density
Authors:ID Put, Florian (Author)
ID Lucherini, Andrea (Author)
ID Merci, Bart (Author)
ID Van Coile, Ruben (Author)
Files:.pdf PDF - Presentation file. (1,16 MB, This file will be accessible after 05.02.2026)
MD5: 85098953ED252D2897926AD343EB9C6F
 
URL URL - Source URL, visit https://doi.org/10.1016/j.firesaf.2024.104113
 
Language:English
Typology:1.01 - Original Scientific Article
Organization:Logo ZAG - Slovenian National Building and Civil Engineering Institute
Abstract:A commonly used approach to represent the thermal load in a compartment fire is the Eurocode Parametric Fire Curve (EPFC), which specifies gas temperatures (or rather adiabatic surface temperatures). Recognizing the significant deviations between real fires and the EPFC framework, the concept of model uncertainty is explored. This study does not aim to assess or improve the EPFC, but introduces a model uncertainty, allowing for reliability-based structural fire engineering (SFE). It presents a stochastic correction factor for the fire load density, based on the maximum temperature in steel sections. The focus is on the fire load density, but in general other parameters can be jointly taken into account as well. This correction factor considers protected and un- protected sections, incorporating variations in section factor and protection thickness. The findings reveal that the fire load density within the EPFC framework can be modified to better represent the severity of fire ex- periments. This approach ensures physical consistency of the obtained compartment gas temperatures, as opposed to alternative approaches for addressing the EPFC model uncertainty. While promising results are evident in this proof of concept, exploration for other types of structural elements and evaluation for structural systems is necessary before integration into design practices.
Keywords:structural fire engineering, compartment fires, fire load density, steel structures, reliability, probability of failure
Publication status:Published
Publication version:Version of Record
Publication date:05.02.2024
Publisher:Elsevier
Year of publishing:2024
Number of pages:str. 1-11
Numbering:Vol. 141, [article no.] 104113
PID:20.500.12556/DiRROS-18677 New window
UDC:62
ISSN on article:1873-7226
DOI:10.1016/j.firesaf.2024.104113 New window
COBISS.SI-ID:191319043 New window
Copyright:© 2024 Elsevier Ltd. All rights reserved.
Note:Opis vira z dne 4. 4. 2024; Nasl. z nasl. zaslona;
Publication date in DiRROS:17.04.2024
Views:69
Downloads:23
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
  
Share:Bookmark and Share


Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Record is a part of a journal

Title:Fire safety journal
Publisher:Elsevier
ISSN:1873-7226
COBISS.SI-ID:87686659 New window

Document is financed by a project

Funder:Other - Other funder or multiple funders
Project number:1137123N
Name:Characterization of the thermal exposure and material properties of concrete during the fire decay phase for performance-based structural fire engineering

Funder:EC - European Commission
Funding programme:H2020
Project number:952395
Name:Fire-safe Sustainable Built Environment
Acronym:FRISSBE

Licences

License:CC BY-NC-ND 4.0, Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
Link:http://creativecommons.org/licenses/by-nc-nd/4.0/
Description:The most restrictive Creative Commons license. This only allows people to download and share the work for no commercial gain and for no other purposes.
Licensing start date:01.03.2024
Applies to:Text and Data Mining valid from 2024-03-01 stm-asf valid from 2024-03-01 stm-asf valid from 2024-03-01 stm-asf valid from 2024-03-01 stm-asf valid from 2024-03-01 stm-asf valid from 2024-03-01

Secondary language

Language:Slovenian
Keywords:gradbeni požarni inženiring, požari v prostorih, gostota požarne obremenitve, jeklene konstrukcije, zanesljivost, verjetnost odpovedi


Back