Digital repository of Slovenian research organisations

Show document
A+ | A- | Help | SLO | ENG

Title:Klinična presoja kakovosti mamogramov
Authors:ID Rener, Miljeva (Author)
ID Hertl, Kristijana (Author)
Files:.pdf PDF - Presentation file, download (674,07 KB)
MD5: 1E15355CAF00110ECC24C55CFCA6CBAB
 
Language:Slovenian
Typology:1.02 - Review Article
Organization:Logo OI - Institute of Oncology
Abstract:Kakovosten mamogram prikaže kar največ tkiva dojke, je primerno ekponiran, kontrasten, ni zabrisan, z nizkim šumom, brez artefaktov in je narejen s sprejemljivo dozo sevanja. Končni videz mamograma je skupek raznih dejavnikov,od katerih so najpomembnejši sodoben mamografski aparat z optimalnonaravnano fotocelico in s sodobnim priborom; posebna pozornost velja postopku razvijanja. Dobro usposobljeno, posebej za to delo izobraženo osebje mora vzdrževati visoko kakovost, to pa pripomore k čim manjšemu številu zgrešenih in zapoznelih diagnoz.
Publication status:Published
Publication version:Version of Record
Publication date:01.01.1999
Publisher:Association of Radiology and Oncology
Year of publishing:1999
Number of pages:str. S13-23
Numbering:Letn. 33, suppl. 2
Source:Ljubljana
PID:20.500.12556/DiRROS-17484 New window
UDC:616-006
ISSN on article:1318-2099
COBISS.SI-ID:10737113 New window
Copyright:by Authors
Note:Zagotavljanje kakovosti v slikovni diagnostiki dojke; BSDOCID48370;
Publication date in DiRROS:08.12.2023
Views:610
Downloads:140
Metadata:XML DC-XML DC-RDF
:
Copy citation
  
Share:Bookmark and Share


Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Record is a part of a journal

Title:Radiology and oncology
Shortened title:Radiol. oncol.
Publisher:Slovenian Medical Society - Section of Radiology, Croatian Medical Association - Croatian Society of Radiology
ISSN:1318-2099
COBISS.SI-ID:32649472 New window

Secondary language

Language:English
Title:Clinical image evaluation
Abstract:Good quality mammogram is characterised by the following features: proper positioning, correct exposition, correct contrast, sharpness, low noise, artefact free execution at acceptable dose. The final product depends on a number of dynamic factors. The most important of them is state-of the art mammographic equipment by optimal calibrated AEC; special attention should be paid to the processing. Highly skilled personel, trained specifically for thiskind of work should continually maintain constant attention to quality control in order to avoid missed and delayed diagnosing.


Back