Abstract:The surface, corrosion and wear properties of new and in vivo exposed nickel titanium (NiTi) and stainless steel (SS) archwires used in orthodontic treatment were investigated. Electrochemical and tribo-electrochemical tests in artificial saliva were performed in order to define corrosion properties and to estimate wear rate of new and in vivo exposed NiTi and SS archwires. The surface chemical analysis of the passive film on the NiTi and SS archwires before and after tribocorrosion tests was performed by Auger Electron Spectroscopy (AES). In vivo exposed NiTi and SS archwires had better electrochemical properties than new archwires due to the protective nature of oral deposits. Total wear and coefficients of friction were higher among in vivo exposed archwires and higher in NiTi archwires in comparison to SS archwires. The estimated thickness of the TiO2 passive film on as-received NiTi is 8 nm, while the passive Cr2O3 film on as-received SS is just 1–2 nm. On in vivo exposed NiTi archwire, a 60–80 nm thick organic film/dental plaque was observed, and on SS, it was thinner, at about 60 nm. This research shows the importance of combining AES with electrochemical testing, to characterize tribocorrosive properties of NiTi and SS orthodontic archwires.
Keywords:archwires, NiTi, stainless steel, wear
Publication status:Published
Publication version:Version of Record
Publication date:03.03.2020
Publisher:MDPI AG
Year of publishing:2020
Number of pages:str. 1-11
Numbering:Vol. 10, iss. 3
PID:20.500.12556/DiRROS-16829 New window
UDC:544.5/.6
ISSN on article:2079-6412
DOI:10.3390/coatings10030230 New window
COBISS.SI-ID:2566759 New window
Copyright:© 2020 by the authors. Licensee MDPI, Basel, Switzerland.
Note:Nasl. z nasl. zaslona; Opis vira z dne 10. 3. 2020; Članek št. 136; Št. članka: 230;
Publication date in DiRROS:24.08.2023
Views:739
Downloads:290
Metadata:XML DC-XML DC-RDF
:
Copy citation
  
Share:Bookmark and Share


Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Record is a part of a journal

Title:Coatings
Shortened title:Coatings
Publisher:MDPI AG
ISSN:2079-6412
COBISS.SI-ID:523035673 New window

Document is financed by a project

Funder:ARRS - Slovenian Research Agency
Project number:L3-5501
Name:Učinkovitost ortodontske obravnave z nesnemnimi ortodontskimi aparati pri različnih površinskih spremembah njihovih kovinskih delov

Funder:ARRS - Slovenian Research Agency
Project number:L2-1831
Name:Implementacija aditivnih tehnologij v stomatološki protetiki

Licences

License:CC BY 4.0, Creative Commons Attribution 4.0 International
Link:http://creativecommons.org/licenses/by/4.0/
Description:This is the standard Creative Commons license that gives others maximum freedom to do what they want with the work as long as they credit the author.

Secondary language

Language:Slovenian
Keywords:ortodontske žice, NiTi, nerjavno jeklo, obraba