Title:Improved seismic response of light-frame-timber panels with cement-particle-board sheathing of various thicknesses and different configurations of fasteners
Authors:ID Kržan, Meta (Author)
ID Pazlar, Tomaž (Author)
ID Ber, Boštjan (Author)
Files:URL URL - Source URL, visit https://www.sciencedirect.com/science/article/pii/S0141029621018381
 
.pdf PDF - Presentation file, download (15,48 MB)
MD5: 843AD13D52770578716ECA4831A9A2E0
 
Language:English
Typology:1.01 - Original Scientific Article
Organization:Logo ZAG - Slovenian National Building and Civil Engineering Institute
Abstract:Due to their comparable fire characteristics and surface preparation, light-frame timber panels using cement-particle boards (CPB) as a sheathing material present a potential alternative to gypsum-fibre boards. An experimental campaign was conducted to evaluate the behaviour of CPB light-frame-timber panels under in-plane lateral loading. Monotonic and cyclic in-plane shear tests were conducted on full-size panels, following preceding tests on the stapled sheathing-to-timber connections used in the panels. The influence of the boards’ thickness and staple geometry on the response of connections and panels was studied, also on panels with an asymmetrical CPB layout, which proved not to have a negative influence on the panels’ lateral load-bearing capacity. Furthermore, in order to improve the seismic response, panels, which had almost twice the number of staples compared to the basic panel, were tested; one variation with two rows of staples, and the other with the staples spaced closer together, such that the spacing distance was halved. The tests revealed a significant, though not proportional, increase in lateral resistance in the strengthened panels. Fastening the CPB with two rows of staples proved the better option, since subsequent failure of the CPB along the connections, as opposed to ductile failure of the staples in the basic panels, proved not to reduce the panels’ deformation capacity. The paper also compares the test results of the connections and panels to analytical results according to Eurocode 5 (EC5), the European code provision for the design of timber structures.
Keywords:light-frame timber panels, cement-particle board sheathing, cyclic shear tests, sheathing-to-timber connection, asymmetrical panel, staple spacing distance, EN 1995–1-1, open access
Publication status:Published
Publication version:Version of Record
Publication date:27.12.2021
Publisher:Elsevier
Year of publishing:2022
Number of pages:str. 1-14
Numbering:Vol. 253
PID:20.500.12556/DiRROS-15809 New window
UDC:624
ISSN on article:1873-7323
DOI:10.1016/j.engstruct.2021.113757 New window
COBISS.SI-ID:92159491 New window
Copyright:© 2021 The Authors. Published by Elsevier Ltd.
Note:Nasl. z nasl. zaslona; Opis vira z dne 5. 1. 2022; Št. članka: 113757;
Publication date in DiRROS:31.05.2023
Views:405
Downloads:192
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
  
Share:Bookmark and Share


Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Record is a part of a journal

Title:Engineering structures
Publisher:Elsevier
ISSN:1873-7323
COBISS.SI-ID:23165701 New window

Document is financed by a project

Funder:ARRS - Slovenian Research Agency
Project number:C3330-19-952045
Name:Raziskovalci-2.1-ZAG-952045

Funder:Other - Other funder or multiple funders
Project number:C3330-16-52900
Name:Trajnostno in inovativno gradbeništvo za pametne stavbe
Acronym:TIGR4smart

Funder:ARRS - Slovenian Research Agency
Project number:P2-0273
Name:Gradbeni objekti in materiali

Licences

License:CC BY 4.0, Creative Commons Attribution 4.0 International
Link:http://creativecommons.org/licenses/by/4.0/
Description:This is the standard Creative Commons license that gives others maximum freedom to do what they want with the work as long as they credit the author.
Licensing start date:14.12.2021
Applies to:Text and Data Mining valid from 2022-02-01 Version of Record valid from 2021-12-14

Secondary language

Language:Slovenian
Keywords:leseni okvirni stenski paneli, cementno iverne obložne plošče, ciklične strižne preiskave, stik obložna plošča - les, nesimetrični panel, razdalja med sponkami, EN 1995–1-1, odprti dostop


Back