Digital repository of Slovenian research organisations

Search the repository
A+ | A- | Help | SLO | ENG

Query: search in
search in
search in
search in

Options:
  Reset


Query: "keywords" (hip) .

1 - 4 / 4
First pagePrevious page1Next pageLast page
1.
Foot posture index and hip joint rotation mobility in handball and soccer players
Tjaž Brezovar, Matej Drobnič, Alan Kacin, 2023, original scientific article

Abstract: Purpose: To assess the foot posture and hip joint mobility of elite handball and soccer players and to investigate possible correlations between these measurements. Methods: We compared the differences in means of Foot Posture Index (FPI), pas-sive hip internal (IR), and external (ER) rotation range of motion (ROM) between three groups of male subjects (17 handball players, 17 soccer players, and 16 non-athletes). The Kruskal-Walli’s test and post-hoc pairwise comparison with the Mann-Whitney U test were used to determine the differences between the group means, and associations between variables were analyzed with Spearman’s correlation coefficient. Results: No significant differences in the mean FPI were found between the soccer players (1.3 ± 2.9), handball players (0.7 ± 2.1), and the control group (1.7 ± 2.5) (p > 0.05). Similarly, no significant difference was found between the groups in the hip ER ROM. In contrast, a significantly lower (p < 0.05) hip IR ROM was observed in the soccer players (30.6° ± 5.3°) compared to the handball players (41.0° ± 8.1°) and the control group (41.1° ± 6.4°). A weak positive correlation was only observed between the FPI and hip IR ROM in the soccer players (ρ: 0.36, p = 0.035). Conclusions: Handball and soccer players show a tendency toward less pronated feet compared to non-athletes, but the differences are not significant and the mean FPI values are still within the range of normal foot posture. The range of hip IR seems to be reduced in soccer players and weakly, but significantly and positively associated with the FPI value, which needs to be further investigated in future studies.
Keywords: foot shape, hip mobility, soccer players, handball players
Published in DiRROS: 17.04.2024; Views: 68; Downloads: 30
URL Link to file
This document has many files! More...

2.
Mechanisms of premature fracture in modular neck stems made of CoCrMo/Ti6Al4V and Ti6Al4V/Ti6Al4V alloy
Drago Dolinar, Miro Gorenšek, Klemen Avsec, Barbara Šetina, Matej Hočevar, Matjaž Godec, Borut Žužek, Mojca Debeljak, Monika Jenko, John T. Grant, Boštjan Kocjančič, 2023, original scientific article

Abstract: In this paper, we present the mechanisms of premature fracture of modular neck stems in two case studies: (I) when the neck and stem are both made of the same Ti6Al4V alloy, and (II) when the neck and stem are made from two different alloys, CoCrMo and Ti6Al4V alloy. Our study integrates two orthopedic patients who have undergone primary uncemented THA for usual indications in two orthopedic centers (Community Health Centre and University Medical Centre). Both centers are part of the national public health care system. Both surgeries were performed by two skilled orthopedic surgeons with more than 10 years of experience in THA. The survivorship of the modular neck of cast CoCrMo alloy was 24 months. The survivorship of the modular neck from Ti6Al4V alloy was 84 months. Multivariate analyses were performed to assess the differences in the fretting, corrosion, and fatigue of the two prematurely failed modular neck stems: stereo light microscopy (SLM), scanning electron microscopy (SEM), X-ray energy-dispersive spectroscopy (EDS), and electron backscatter diffraction (EBSD). Patient demographic information, including sex, age, body mass index, survivorship of implants, and reason for the revision, was collected from medical records. We found that fretting and fatigue occurred on both neck-stem retrievals due to additional galvanic corrosion, but the CoCrMo/Ti6Al4V alloy system suffered more corrosion due to additional galvanic corrosion and fractured earlier than the Ti6Al4V/Ti6Al4V metal alloy system. Both metallic alloy systems used in this application are known to be highly corrosion-resistant, but the bio-tribo-corrosion processes need to be understood in detail and characterized so that appropriate improvements in design and materials can be made.
Keywords: total hip arthroplasty, modular neck, Ti6Al4V alloy, CoCrMo alloy, corrosion
Published in DiRROS: 07.02.2024; Views: 229; Downloads: 126
.pdf Full text (5,12 MB)
This document has many files! More...

3.
4.
Fat mass to fat- free mass ratio and body composition in participants with chronic leg problems
Mihaela Jurdana, Ana Tomažič, Boštjan Žvanut, 2022, original scientific article

Keywords: fat-mass, fat-free mass, waist circumference, older adults, knee, hip
Published in DiRROS: 20.04.2023; Views: 317; Downloads: 205
.pdf Full text (494,83 KB)
This document has many files! More...

Search done in 0.13 sec.
Back to top