Digital repository of Slovenian research organisations

Search the repository
A+ | A- | Help | SLO | ENG

Query: search in
search in
search in
search in

Options:
  Reset


Query: "keywords" (failure mechanisms) .

1 - 2 / 2
First pagePrevious page1Next pageLast page
1.
Experimental investigation of the axial strength of glued-in rods in cross laminated timber
Boris Azinović, Erik Serrano, Miha Kramar, Tomaž Pazlar, 2018, original scientific article

Abstract: This paper presents results from an experimental assessment of glued-in rods in cross laminated timber (CLT). For the purposes of the study more than 60 pull-pull tests were performed, where the specimens varied in terms of bonded-in length (from 80 to 400 mm), rod diameter (16-24 mm) and rod-to-grain angle (parallel and perpendicular). Several different failure modes that are not common for other applications of glued-in rods (e.g., a failure between CLT layers) were obtained for the analysed CLT specimens. It was found that these failure mechanisms can substantially influence the obtained ultimate tension loads. At the end, the experimental results were compared with empirical and semi-empirical equations for estimating the pull-out strength of glued-in rods in structural timber and glulam. The comparison showed that most of the existing equations overestimate the ultimate tension loads for specimens with the rod parallel to the grain and underestimate the ultimate tension load for specimens with the rod perpendicular to the grain. The results vary because the possible CLT failure modes were not included in previous studies. Further studies are proposed to improve the equations for glued-in rods in CLT.
Keywords: glued-in rods, cross laminated timber (CLT), pull-pull experiment, glued-in length, rod-to-grain angle, failure mechanisms in CLT
Published in DiRROS: 29.11.2023; Views: 219; Downloads: 177
.pdf Full text (4,13 MB)
This document has many files! More...

2.
In-plane seismic behaviour of ashlar three-leaf stone masonry walls : verifying performance limits
Meta Kržan, Vlatko Bosiljkov, 2021, original scientific article

Abstract: In light of the forthcoming second generation Eurocodes (EC), the results of conducted systematic in-plane cyclic and compressive tests on three-leaf stone masonry walls are discussed following new requirements and provisions. The new proposal for EC8-3 for existing buildings is based on partial factors safety approach, though it considers different uncertainties in defining input parameters for effective seismic performance-based assessment. Prior to its application, massive calibration effort will be needed since there is no standardized method for shear testing of masonry walls. In this paper, the performance limit states damage, resistance, and displacement capacities from conducted test results were evaluated and assessed through comparison with analytical solutions and imposed limit values, as stated in existing codes. The test results provide a much higher deformation capacity than the limits provided in both existing and new proposal of EC8-3 as well as those in the ASCE code provisions. The reason for this lies in the soft, "ductile" mortar for which the presumed resistance according to code provisions should be significantly higher when considering good quality ashlar three-leaf stone masonry.
Keywords: historical masonry, multi-leaf stone masonry, mechanical properties, compression tests, in-plane shear tests, failure mechanisms, drift limits, boundary conditions
Published in DiRROS: 19.05.2023; Views: 322; Downloads: 163
.pdf Full text (4,47 MB)
This document has many files! More...

Search done in 0.03 sec.
Back to top