Naslov:Safe implementation of robotic colorectal surgery : balancing surgical training and patient safety with the dual-console system
Avtorji:ID Košir, Jurij Aleš (Avtor)
ID Petrič, Miha (Avtor)
ID Trotovšek, Blaž (Avtor)
ID Norčič, Gregor (Avtor)
ID Grosek, Jan (Avtor)
Datoteke:.pdf PDF - Predstavitvena datoteka, prenos (408,58 KB)
MD5: 51CA5B1457279490DFA65FB2793E0FF5
 
URL URL - Izvorni URL, za dostop obiščite https://www.mdpi.com/2077-0383/15/14/5669
 
Jezik:Angleški jezik
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:Logo UKC LJ - Univerzitetni klinični center Ljubljana
Povzetek:Background: Robotic platforms expand minimally invasive options in colorectal surgery but raise concerns about training and patient safety. Dual-console systems may enable realtime coaching while preserving outcomes. Methods: We implemented a structured framework for safe implementation of robotic colorectal surgery that balances trainee autonomy with patient safety using a dual-console model. Early cases emphasized low-complexity pathology with escalation by predefined benchmarks. We prospectively gathered data and evaluated early program outcomes with primary endpoints including intraoperative adverse events, conversion to open surgery, 30-day morbidity, anastomotic integrity, and oncologic quality metrics. Secondary endpoints included operative time. Results: We included the analysis of 17 patients operated by one surgeon under supervision and compared the results to other senior colorectal surgeons. Out of the 17 patients, there were no conversions or anastomotic leaks. Overall complications were comparable to baseline robotic cases. Resection margins and lymph node yields met oncologic standards. Operative times were longer during early adoption but approached baseline with progression. Operative times were significantly reduced after eight cases and approached the times of senior surgeons after 13 cases. Conclusions: A dual-console strategy enables safe, scalable training in robotic colorectal surgery without compromising short-term patient outcomes or oncologic quality. Key elements include rigorous case selection, proficiency-based progression, real-time coaching, standardized protocols, and continuous data surveillance. This framework can guide institutions seeking to expand robotic colorectal programs while safeguarding patients and accelerating the learning curve.
Ključne besede:robotic colorectal surgery, learning curve, safe implementation, complications
Status publikacije:Objavljeno
Verzija publikacije:Objavljena publikacija
Leto izida:2026
Št. strani:str. 1-7
Številčenje:Vol. 15, iss. 14, [article no.] 5669
PID:20.500.12556/DiRROS-31184 Novo okno
UDK:617
ISSN pri članku:2077-0383
DOI:10.3390/jcm15145669 Novo okno
COBISS.SI-ID:285399299 Novo okno
Opomba:Nasl. z nasl. zaslona; Opis vira z dne 20. 7. 2026;
Datum objave v DiRROS:20.07.2026
Število ogledov:121
Število prenosov:73
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
  
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del revije

Naslov:Journal of clinical medicine
Skrajšan naslov:J. clin. med.
Založnik:MDPI
ISSN:2077-0383
COBISS.SI-ID:5405759 Novo okno

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Nazaj