Digitalni repozitorij raziskovalnih organizacij Slovenije

Izpis gradiva
A+ | A- | Pomoč | SLO | ENG

Naslov:Introduction of a spectrophotometric method for salivary iodine determination on microplate based on Sandell-Kolthoff reaction
Avtorji:ID Oblak, Adrijana (Avtor)
ID Imperl, Jernej (Avtor)
ID Kolar, Mitja (Avtor)
ID Marolt, Gregor (Avtor)
ID Krhin, Blaž (Avtor)
ID Zaletel, Katja (Avtor)
ID Gaberšček, Simona (Avtor)
Datoteke:URL URL - Izvorni URL, za dostop obiščite https://sciendo.com/article/10.2478/raon-2024-0035
 
.pdf PDF - Predstavitvena datoteka, prenos (763,51 KB)
MD5: 86A497BC695BC4403DF77544B9F36054
 
Jezik:Angleški jezik
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:Logo DRO - Društvo radiologije in onkologije
Povzetek:Background. Iodine is an essential element for the synthesis of thyroid hormones. Therefore, a reliable marker of iodine supply is important. Iodine is predominantly excreted via kidneys, but also via salivary glands. Our aim was to introduce a new and simple method for determination of salivary iodine concentration (SLIC). Materials and methods. Self-prepared chemicals and standards for Sandell-Kolthoff reaction on microplate with ammonium peroxydisulfate (AP) in the range 0−400 µg/L were used. Suitability of water-based standards (WBS) and artificial saliva-based standards (ASS) for standard curve were tested. We followed standards for method validation, defined concentration of used AP and compared our results with Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Results. WBS gave more reliable results than ASS as an underestimation of iodine concentration was found for ASS. LoB was 6.5 µg/L, LoD 12.0 µg/L, therefore analytical range was 12−400 µg/L. Intra- and inter-assay imprecisions at iodine concentrations, namely 20, 100, 165, and 350 µg/L were 18.4, 5.1, 5.7, and 2.8%, respectively, and 20.7, 6.7, 5.1, and 4.3%, respectively. Suitable molarity of AP was 1.0 mol/L and showed no difference to 1.5 mol/L (P values for samples with concentration 40, 100, and 150 µg/L, were 0.761, 0.085, and 0.275, respectively), whereas there was a significant change using 0.5 mol/L (P<0.001). Saliva samples could be diluted up to 1:8. There was no interference of thiocyanate and caffeine up to 193.5 mg/L. Our original method was comparable to ICP-MS. Spaerman coefficient was 0.989 (95% CI: 0.984−0.993). Conclusions. The new method for SLIC determination is in excellent agreement with ICP-MS and easy-to-use.
Ključne besede:iodine, salivary iodine concentration, Sandell-Kolthoff reaction
Status publikacije:Objavljeno
Verzija publikacije:Objavljena publikacija
Datum objave:01.09.2024
Založnik:Association of Radiology and Oncology
Leto izida:2024
Št. strani:str. 357-365, V
Številčenje:Vol. 58, no. 3
Izvor:Ljubljana
PID:20.500.12556/DiRROS-30466 Novo okno
UDK:61
ISSN pri članku:1318-2099
DOI:10.2478/raon-2024-0035 Novo okno
COBISS.SI-ID:204612355 Novo okno
Opomba:Soavtorji: Jernej Imperl, Mitja Kolar, Gregor Marolt, Blaz Krhin, Katja Zaletel, Simona Gaberscek;
Datum objave v DiRROS:26.06.2026
Število ogledov:25
Število prenosov:18
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
  
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del revije

Naslov:Radiology and oncology
Skrajšan naslov:Radiol. oncol.
Založnik:Slovenian Medical Society - Section of Radiology, Croatian Medical Association - Croatian Society of Radiology
ISSN:1318-2099
COBISS.SI-ID:32649472 Novo okno

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Sekundarni jezik

Jezik:Slovenski jezik
Naslov:Uvedba spektrofotometrične metode za določanje joda v slini s pomočjo Snadell-Kolthoffove reakcije na mikrotitrski ploščici


Nazaj