| Naslov: | Introduction of a spectrophotometric method for salivary iodine determination on microplate based on Sandell-Kolthoff reaction |
|---|
| Avtorji: | ID Oblak, Adrijana (Avtor) ID Imperl, Jernej (Avtor) ID Kolar, Mitja (Avtor) ID Marolt, Gregor (Avtor) ID Krhin, Blaž (Avtor) ID Zaletel, Katja (Avtor) ID Gaberšček, Simona (Avtor) |
| Datoteke: | URL - Izvorni URL, za dostop obiščite https://sciendo.com/article/10.2478/raon-2024-0035
PDF - Predstavitvena datoteka, prenos (763,51 KB) MD5: 86A497BC695BC4403DF77544B9F36054
|
|---|
| Jezik: | Angleški jezik |
|---|
| Tipologija: | 1.01 - Izvirni znanstveni članek |
|---|
| Organizacija: | DRO - Društvo radiologije in onkologije
|
|---|
| Povzetek: | Background. Iodine is an essential element for the synthesis of thyroid hormones. Therefore, a reliable marker of iodine supply is important. Iodine is predominantly excreted via kidneys, but also via salivary glands. Our aim was to introduce a new and simple method for determination of salivary iodine concentration (SLIC). Materials and methods. Self-prepared chemicals and standards for Sandell-Kolthoff reaction on microplate with ammonium peroxydisulfate (AP) in the range 0−400 µg/L were used. Suitability of water-based standards (WBS) and artificial saliva-based standards (ASS) for standard curve were tested. We followed standards for method validation, defined concentration of used AP and compared our results with Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Results. WBS gave more reliable results than ASS as an underestimation of iodine concentration was found for ASS. LoB was 6.5 µg/L, LoD 12.0 µg/L, therefore analytical range was 12−400 µg/L. Intra- and inter-assay imprecisions at iodine concentrations, namely 20, 100, 165, and 350 µg/L were 18.4, 5.1, 5.7, and 2.8%, respectively, and 20.7, 6.7, 5.1, and 4.3%, respectively. Suitable molarity of AP was 1.0 mol/L and showed no difference to 1.5 mol/L (P values for samples with concentration 40, 100, and 150 µg/L, were 0.761, 0.085, and 0.275, respectively), whereas there was a significant change using 0.5 mol/L (P<0.001). Saliva samples could be diluted up to 1:8. There was no interference of thiocyanate and caffeine up to 193.5 mg/L. Our original method was comparable to ICP-MS. Spaerman coefficient was 0.989 (95% CI: 0.984−0.993). Conclusions. The new method for SLIC determination is in excellent agreement with ICP-MS and easy-to-use. |
|---|
| Ključne besede: | iodine, salivary iodine concentration, Sandell-Kolthoff reaction |
|---|
| Status publikacije: | Objavljeno |
|---|
| Verzija publikacije: | Objavljena publikacija |
|---|
| Datum objave: | 01.09.2024 |
|---|
| Založnik: | Association of Radiology and Oncology |
|---|
| Leto izida: | 2024 |
|---|
| Št. strani: | str. 357-365, V |
|---|
| Številčenje: | Vol. 58, no. 3 |
|---|
| Izvor: | Ljubljana |
|---|
| PID: | 20.500.12556/DiRROS-30466  |
|---|
| UDK: | 61 |
|---|
| ISSN pri članku: | 1318-2099 |
|---|
| DOI: | 10.2478/raon-2024-0035  |
|---|
| COBISS.SI-ID: | 204612355  |
|---|
| Opomba: | Soavtorji: Jernej Imperl, Mitja Kolar, Gregor Marolt, Blaz Krhin, Katja Zaletel, Simona Gaberscek;
|
|---|
| Datum objave v DiRROS: | 26.06.2026 |
|---|
| Število ogledov: | 25 |
|---|
| Število prenosov: | 18 |
|---|
| Metapodatki: |  |
|---|
|
:
|