Naslov:Intra‐rater and inter‐rater reliability of robotic arthrometer DYNEELAX®
Avtorji:ID Mihalinec, Katja (Avtor)
ID Martinez-Cepa, Carmen B. (Avtor)
ID Zuil-Escobar, Juan C. (Avtor)
ID Kejžar, Nataša (Avtor)
ID Vauhnik, Renata (Avtor)
Datoteke:.pdf PDF - Predstavitvena datoteka, prenos (171,19 KB)
MD5: DC72B485C9403184ED142349C0394747
 
URL URL - Izvorni URL, za dostop obiščite https://esskajournals.onlinelibrary.wiley.com/doi/10.1002/jeo2.70026
 
Jezik:Angleški jezik
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:Logo UKC LJ - Univerzitetni klinični center Ljubljana
Povzetek:Purpose: The purpose of our study was to test the intra-rater and inter-rater reliability of the DYNEELAX® arthrometer in healthy subjects. Since rotational laxity will be measured for the first time in humans, indications for normative values will also be presented. Methods: Knee anterior laxity and rotational laxity using a DYNEELAX® arthrometer were assessed in 73 subjects (39 females and 34 males). An intraclass correlation coefficient was calculated to evaluate the intra-rater and inter-rater reliability of the DYNEELAX®. Results: An intraclass correlation coefficient for intra-rater reliability ranges from 0.631 (95% confidence interval; [CI]: 0.47–0.75) to 0.699 (95% CI: 0.56–0.80) and from 0.916 (95% CI: 0.87–0.95) to 0.94 (95% CI: 0.91–0.96) for anterior knee laxity and rotational knee laxity, respectively. An intraclass correlation coefficient for inter-rater reliability ranges from 0.578 (95% CI: 0.40–0.71) to 0.646 (95% CI: 0.44–0.78) and from 0.822 (95% CI: 0.57–0.91) to 0.933 (95% CI: 0.89–0.96) for anterior knee laxity and rotational knee laxity, respectively. Conclusions: The DYNEELAX® arthrometer has good to excellent intra-rater and inter-rater reliability for rotational knee laxity and moderate intra-rater reliability for anterior knee laxity in healthy subjects. Future studies should investigate the clinical significance of anterior and rotational laxity measured with the DYNEELAX® arthrometer in patients with knee pathology, as both laxities are critical for assessing the integrity of the intra-articular structures of the knee in clinical practice.
Ključne besede:anterior laxity, arthrometry, rotational laxity, reliability
Status publikacije:Objavljeno
Verzija publikacije:Objavljena publikacija
Leto izida:2024
Št. strani:str. 1-9
Številčenje:Vol. 11, issue 4, [article no.] e70026
PID:20.500.12556/DiRROS-29177 Novo okno
UDK:615.82/.84:616.728.3
ISSN pri članku:2197-1153
DOI:10.1002/jeo2.70026 Novo okno
COBISS.SI-ID:209810179 Novo okno
Opomba:Nasl. z nasl. zaslona; Opis vira z dne 2. 10. 2024;
Datum objave v DiRROS:23.04.2026
Število ogledov:58
Število prenosov:46
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
  
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del revije

Naslov:Journal of experimental orthopaedics
Skrajšan naslov:J. exp. orthop.
Založnik:Springer
ISSN:2197-1153
COBISS.SI-ID:520470809 Novo okno

Gradivo je financirano iz projekta

Financer:ARIS - Javna agencija za znanstvenoraziskovalno in inovacijsko dejavnost Republike Slovenije
Številka projekta:P3-0388-2022
Naslov:Mehanizmi varovanja zdravja

Financer:ARIS - Javna agencija za znanstvenoraziskovalno in inovacijsko dejavnost Republike Slovenije
Številka projekta:P3-0154-2022
Naslov:Metodologija za analizo podatkov v medicini

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:anteriorna ohlapnost, artrometrija, rotacijska ohlapnost, zanesljivost