Digitalni repozitorij raziskovalnih organizacij Slovenije

Izpis gradiva
A+ | A- | Pomoč | SLO | ENG

Naslov:Evaluation of neonatal screening programs for tyrosinemia type 1 worldwide
Avtorji:ID Kuypers, Allysa M. (Avtor)
ID Bouva, Marelle J. (Avtor)
ID Loeber, J. Gerard (Avtor)
ID Boelen, Anita (Avtor)
ID Dekkers, Eugenie (Avtor)
ID Petritis, Konstantinos (Avtor)
ID Pickens, C. Austin (Avtor)
ID Spronsen, Francjan J. van (Avtor)
ID Heiner-Fokkema, M. Rebecca (Avtor)
ID Grošelj, Urh (Sodelavec pri raziskavi)
ID Repič-Lampret, Barbka (Sodelavec pri raziskavi), et al.
Datoteke:.pdf PDF - Predstavitvena datoteka, prenos (2,24 MB)
MD5: 8C995A5733758FB8CD42A5FDCCA59D12
 
URL URL - Izvorni URL, za dostop obiščite https://www.mdpi.com/2409-515X/10/4/82/pdf?version=1734602740
 
Jezik:Angleški jezik
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:Logo UKC LJ - Univerzitetni klinični center Ljubljana
Povzetek:In The Netherlands, newborn screening (NBS) for tyrosinemia type 1 (TT1) uses dried blood spot (DBS) succinylacetone (SUAC) as a biomarker. However, high false-positive (FP) rates and a false-negative (FN) case show that the Dutch TT1 NBS protocol is suboptimal. In search of optimization options, we evaluated the protocols used by other NBS programs and their performance. We distributed an online survey to NBS program representatives worldwide (N = 41). Questions focused on the organization and performance of the programs and on changes since implementation. Thirty-three representatives completed the survey. TT1 incidence ranged from 1/13,636 to 1/750,000. Most NBS samples are taken between 36 and 72 h after birth. Most used biomarkers were DBS SUAC (78.9%), DBS Tyrosine (Tyr; 5.3%), or DBS Tyr with second tier SUAC (15.8%). The pooled median cut-off for SUAC was 1.50 µmol/L (range 0.3–7.0 µmol/L). The median cut-off from programs using laboratory-developed tests was significantly higher (2.63 µmol/L) than the medians from programs using commercial kits (range 1.0–1.7 µmol/L). The pooled median cut-off for Tyr was 216 µmol/L (range 120–600 µmol/L). Overall positive predictive values were 27.3% for SUAC, 1.2% for Tyr solely, and 90.1% for Tyr + SUAC. One FN result was reported for TT1 NBS using SUAC, while three FN results were reported for TT1 NBS using Tyr. The NBS programs for TT1 vary worldwide in terms of analytical methods, biochemical markers, and cut-off values. There is room for improvement through method standardization, cut-off adaptation, and integration of new biomarkers. Further enhancement is likely to be achieved by the application of post-analytical tools
Ključne besede:tyrosinemia type 1, neonatal screening, dried blood spots, inborn metabolic disease, succinylacetone, tyrosine
Status publikacije:Objavljeno
Verzija publikacije:Objavljena publikacija
Leto izida:2024
Št. strani:str. 1-23
Številčenje:Vol. 10, iss. 4, ǂ[article no.] ǂ82
PID:20.500.12556/DiRROS-27880 Novo okno
UDK:616-053.2
ISSN pri članku:2409-515X
DOI:10.3390/ijns10040082 Novo okno
COBISS.SI-ID:230729219 Novo okno
Opomba:Nasl. z nasl. zaslona; Opis vira z dne 30. 3. 2025;
Datum objave v DiRROS:26.02.2026
Število ogledov:127
Število prenosov:56
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
  
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del revije

Naslov:International journal of neonatal screening
Skrajšan naslov:Int. j. neonatal screen.
Založnik:MDPI AG
ISSN:2409-515X
COBISS.SI-ID:525322521 Novo okno

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Nazaj