Povzetek:Background The total amount of heparin administered through flush fluids in stroke patients is not considered in recent trials, possibly influencing main results. We investigated the use of heparin among treating physicians worldwide. Methods We conducted a survey from November 2022 to January 2023 to identify the variability of heparin administration during stroke endovascular treatment (EVT). We calculated the total heparin dose per hour (IU/h) by adding the intravenous (IV)-bolus dose to the amount administered through flush fluids, calculated by a multiplication of the number of infusion bags, drip rate[mL/h] and heparin concentration[IU/L]. Results A total of 315 participants from different countries worldwide completed the survey and 231/315(73%) respondents administer heparin during EVT. The majority administered heparin only through flush fluids (168/231; 72.7%), followed by both IV-bolus and flush fluids (36/231; 16%), and those who used only an IV-bolus (27/231; 11.7%). From the participants that administer heparin through flush fluids, the median heparin concentration was 2000 IU/L (range:100 IU/L-10000 IU/L). The total heparin dose (administered through flush fluids and IV-bolus) among 23 respondents showed a median of 4650 IU/h (IQR:3432–5900). Among the respondents who administer heparin through IV-bolus only, the median was 5250 IU (IQR:3750–7500). Conclusion This survey revealed variable heparin doses administered by physicians worldwide during EVT and reflects the lack of international guidelines. Caution is warranted, specifically during complex/long EVT procedures. Furthermore, heparin flush doses should be considered in future trials regarding periprocedural anticoagulants, since imbalances could potentially confound results.
Ključne besede:heparin, endovascular treatment, stroke
Status publikacije:Objavljeno
Verzija publikacije:Objavljena publikacija
Leto izida:2025
Št. strani:1 spletni vir (1 datoteka PDF (7 str.)
Številčenje:Vol. 8, issue 17
PID:20.500.12556/DiRROS-27878 Novo okno
UDK:61
ISSN pri članku:2520-8934
DOI:10.1186/s42155-025-00532-3 Novo okno
COBISS.SI-ID:230466051 Novo okno
Opomba:Nasl. z nasl. zaslona; Opis vira z dne 27. 3. 2025;
Datum objave v DiRROS:26.02.2026
Število ogledov:101
Število prenosov:57
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
  
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del revije

Naslov:CVIR endovascular
Skrajšan naslov:CVIR Endovasc
Založnik:Springer International Publishing
ISSN:2520-8934
COBISS.SI-ID:529774105 Novo okno

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Nazaj