Digitalni repozitorij raziskovalnih organizacij Slovenije

Izpis gradiva
A+ | A- | Pomoč | SLO | ENG

Naslov:Anakinra during pregnancy and lactation for corticosteroid-dependant colchicine-resistant recurrent pericarditis in a patient with neutralizing anti-interleukin-1 receptor antagonist antibodies : a case report
Avtorji:ID Černe Čerček, Andreja (Avtor)
ID Gomišček, Alja (Avtor)
ID Trojner-Bregar, Andreja (Avtor)
ID Avčin, Tadej (Avtor)
ID Kessel, Christoph (Avtor)
ID Thurner, Lorenz (Avtor)
ID Fadle, Natalie (Avtor)
ID Čerček, Miha (Avtor)
Datoteke:.pdf PDF - Predstavitvena datoteka, prenos (664,38 KB)
MD5: EF034FE1F2EFCE54E65123E04EF00A8E
 
URL URL - Izvorni URL, za dostop obiščite https://academic.oup.com/ehjcr/article/9/6/ytaf280/8157045?login=false
 
Jezik:Angleški jezik
Tipologija:1.03 - Drugi znanstveni članki
Organizacija:Logo UKC LJ - Univerzitetni klinični center Ljubljana
Povzetek:Background Failure of a small surgical aortic bioprosthesis represents a challenging clinical scenario with valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) often resulting in patient-prosthesis mismatch. Bioprosthetic valve fracture (BVF) performed as a part of the ViV TAVI has recently emerged as an alternative approach with certain types of surgical bioprostheses. Case summary An 81-year-old woman with a history of three surgical aortic valve procedures presented with heart failure. Aortic bioprosthesis degeneration with severe stenosis and moderate regurgitation was found. The patient was deemed a high-risk surgical candidate and the heart team decided that ViV TAVI was the preferred treatment option. Due to the very small 19 mm stented surgical aortic bioprosthesis Mitroflow 19 mm (Sorin Group, Italy) we decided to perform BVF as a part of ViV TAVI to prevent patient-prosthesis mismatch. Since this was the first BVF procedure in our centre, an ex vivo BVF of the same kind of bioprosthetic valve was performed first. Subsequently, successful BVF with implantation of Evolut R 23 mm (Medtronic, USA) self-expandable transcatheter valve was performed. Excellent haemodynamic result was achieved and no periprocedural complications were present. The patient had an immediate major improvement in clinical status and remains asymptomatic after 6-months. Discussion Bioprosthetic valve fracture together with ViV TAVI is a safe and effective emerging technique for treatment of small surgical aortic bioprosthesis failure. Bioprosthetic valve fracture allows marked oversizing of implanted self-expandable transcatheter aortic valves, leading to excellent haemodynamic and clinical results. An ex vivo BVF can serve as an important preparatory step when introducing the new method.
Ključne besede:recurrent pericarditis, case report, anakinra, antibodies against il-1 receptor antagonists, pregnancy
Status publikacije:Objavljeno
Verzija publikacije:Objavljena publikacija
Leto izida:2025
Št. strani:str.1-7
Številčenje:Vol. 9, issue 6
PID:20.500.12556/DiRROS-27759 Novo okno
UDK:61
ISSN pri članku:2514-2119
DOI:10.1093/ehjcr/ytaf280 Novo okno
COBISS.SI-ID:251291907 Novo okno
Opomba:Nasl. z nasl. zaslona 1. 10. 2025; Opis vira z dne 1.10. 2025;
Datum objave v DiRROS:24.02.2026
Število ogledov:160
Število prenosov:65
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
  
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del revije

Naslov:European heart journal : Case reports.
Založnik:Oxford University Press
ISSN:2514-2119
COBISS.SI-ID:529759257 Novo okno

Licence

Licenca:CC BY-NC 4.0, Creative Commons Priznanje avtorstva-Nekomercialno 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by-nc/4.0/deed.sl
Opis:Licenca Creative Commons, ki prepoveduje komercialno uporabo, vendar uporabniki ne rabijo upravljati materialnih avtorskih pravic na izpeljanih delih z enako licenco.

Nazaj