Digitalni repozitorij raziskovalnih organizacij Slovenije

Izpis gradiva
A+ | A- | Pomoč | SLO | ENG

Naslov:Comparison of self-collected and healthcare worker-collected rectovaginal swabs for group B streptococcus detection in pregnancy using PCR with a commercial collection-enrichment device
Avtorji:ID Kukovica, Iva (Avtor)
ID Omahen, Neža (Avtor)
ID Klobučar, Nika (Avtor)
ID Bučar, Martina (Avtor)
ID Franko Rutar, Anita (Avtor)
ID Perme, Tina (Avtor)
ID Lučovnik, Miha (Avtor)
ID Jeverica, Samo (Avtor)
Datoteke:.pdf PDF - Predstavitvena datoteka, prenos (214,14 KB)
MD5: 8AADB8C28CD0673D2274F5C99AE04AE7
 
URL URL - Izvorni URL, za dostop obiščite https://www.frontiersin.org/journals/microbiology/articles/10.3389/fmicb.2025.1541319/full
 
Jezik:Angleški jezik
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:Logo UKC LJ - Univerzitetni klinični center Ljubljana
Povzetek:Introduction: Universal screening for the detection of group B streptococcus (GBS) colonization in pregnant women was recently introduced in Slovenia. The aim of our study was to determine whether self-collection of rectovaginal swabs is a valid alternative to collection by healthcare workers (HCWs). Methods: A prospective, multicenter study was conducted between June and November 2023. A total of 227 pregnant women (aged 20 to 44 years) from the University Medical Center Ljubljana (n = 136), the Novo mesto Community Health Center (n = 48) and the Trebnje Community Health Center (n = 43) were included. Two swabs were taken: swab A by the HCWs using standard semi-solid Amies transport medium (Meus; current standard) and swab B by the pregnant woman following visual instructions using a commercial LIM Broth (Copan). Swabs were inoculated onto ChromID Strepto B (STRB) agars directly and after overnight enrichment in LIM broth. The NeuMoDx GBS assay was performed from the enrichment broth. A self-assessment questionnaire was completed after sampling. Performance characteristics were calculated and compared between different diagnostics test algorithms using McNemar’s test for paired samples. Results: Overall, GBS was detected in 18% (95% CI 13–23%; n = 40) of swabs A and 19% (95% CI 14–25%; n = 43) of swabs B. PCR was superior in both groups. In the group of swabs collected by HCWs, 4 (40 vs. 36; 11.1% difference; p = 0.046) and 3 (40 vs. 37; 8.1% difference; p = 0.083) additional positives were detected with PCR compared to direct and enrichment culture, respectively; in the group of self-collected swabs, 4 (43 vs. 39; 10.3% difference; p = 0.046) and 6 (43 vs. 36; 16.2% difference; p = 0.014) additional positives were detected with PCR compared to direct and enrichment culture, respectively. Self-collection showed a trend towards a higher diagnostic yield. PCR after enrichment from self-collected samples was found to be the most. sensitive method overall. 58.5% (n = 124/212; 95% CI 52–65%) of women would prefer the swabs taken by HCWs. Discussion: Self-collection of rectovaginal swabs during pregnancy is a good alternative to HCW-collected swabs. PCR from enrichment broth was better for the detection of GBS compared to enrichment culture. Majority of women preferred swabs taken by HCWs.
Ključne besede:group B streptococcus, self-collection, enrichment culture, PCR, chromogenic agar, pregnancy, screening
Status publikacije:Objavljeno
Verzija publikacije:Objavljena publikacija
Leto izida:2025
Št. strani:8 str.
Številčenje:Vol. 16, [article no.] 1541319
PID:20.500.12556/DiRROS-24478 Novo okno
UDK:618.1
ISSN pri članku:1664-302X
DOI:10.3389/fmicb.2025.1541319 Novo okno
COBISS.SI-ID:225553667 Novo okno
Opomba:Nasl. z nasl. zaslona; Opis vira z dne 9. 2. 2025;
Datum objave v DiRROS:01.12.2025
Število ogledov:91
Število prenosov:46
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
  
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del revije

Naslov:Frontiers in microbiology
Skrajšan naslov:Front. microbiol.
Založnik:Frontiers Research Foundation
ISSN:1664-302X
COBISS.SI-ID:4146296 Novo okno

Gradivo je financirano iz projekta

Financer:ARIS - Javna agencija za znanstvenoraziskovalno in inovacijsko dejavnost Republike Slovenije
Številka projekta:J7-4418-2022
Naslov:Nanovlakna za sočasno dostavo koktajlov izbrane mikrobiote in protimikrobnih učinkovin za lokalno zdravljenje vaginalnih infekcij

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Nazaj