Naslov:A protocol for accurate radiochromic film dosimetry using Radiochromic.com
Avtorji:ID Méndez Carot, Ignasi (Avtor)
ID Rovira-Escutia, Juan José (Avtor)
ID Casar, Božidar (Avtor)
Datoteke:URL URL - Izvorni URL, za dostop obiščite https://www.sciendo.com/article/10.2478/raon-2021-0034
 
.pdf PDF - Predstavitvena datoteka, prenos (1,85 MB)
MD5: 93F4FA54886D42F1114AD37668739BE4
 
Jezik:Angleški jezik
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:Logo OI - Onkološki inštitut Ljubljana
Povzetek:Radiochromic films have many applications in radiology and radiation therapy. Generally, the dosim-etry system for radiochromic film dosimetry is composed of radiochromic films, flatbed scanner, and film analysis soft-ware. The purpose of this work is to present the effectiveness of a protocol for accurate radiochromic film dosimetry using Radiochromic.com as software for film analysis.Materials and methods. Procedures for image acquisition, lot calibration, and dose calculation are explained and analyzed. Radiochromic.com enables state-of-the-art models and corrections for radiochromic film dosimetry, such as the Multigaussian model for multichannel film dosimetry, and lateral, inter-scan, and re-calibration corrections of the response.Results. The protocol presented here provides accurate dose results by mitigating the sources of uncertainty that affect radiochromic film dosimetry. Conclusions. Appropriate procedures for film and scanner handling in combination with Radiochromic.com as software for film analysis make easy and accurate radiochromic film dosimetry feasible.
Ključne besede:radiochromic film, dosimetry, protocol
Status publikacije:Objavljeno
Verzija publikacije:Objavljena publikacija
Datum objave:01.01.2021
Založnik:Association of Radiology and Oncology
Leto izida:2021
Št. strani:str. 369-378
Številčenje:Vol. 55, no. 3
Izvor:Ljubljana
PID:20.500.12556/DiRROS-19618 Novo okno
UDK:616-07
ISSN pri članku:1318-2099
DOI:10.2478/raon-2021-0034 Novo okno
COBISS.SI-ID:77943043 Novo okno
Avtorske pravice:by Authors
Datum objave v DiRROS:22.07.2024
Število ogledov:333
Število prenosov:186
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
  
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del revije

Naslov:Radiology and oncology
Skrajšan naslov:Radiol. oncol.
Založnik:Slovenian Medical Society - Section of Radiology, Croatian Medical Association - Croatian Society of Radiology
ISSN:1318-2099
COBISS.SI-ID:32649472 Novo okno

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:radiokromski film, dozimetrija, protokoli


Nazaj