Naslov:Uncertainties in target volume delineation in radiotherapy : are they relevant and what can we do about them?
Avtorji:ID Šegedin, Barbara (Avtor)
ID Petrič, Primož (Avtor)
Datoteke:URL URL - Izvorni URL, za dostop obiščite https://www.degruyter.com/downloadpdf/j/raon.2016.50.issue-3/raon-2016-0023/raon-2016-0023.xml
 
.pdf PDF - Predstavitvena datoteka, prenos (904,32 KB)
MD5: 8832F1D22DDB6F06E217DB56EA1F9E41
 
Jezik:Angleški jezik
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:Logo OI - Onkološki inštitut Ljubljana
Povzetek:Modern radiotherapy techniques enable delivery of high doses to the target volume without escalating dose to organs at risk, offering the possibility of better local control while preserving good quality of life. Uncertainties in target volume delineation have been demonstrated for most tumour sites, and various studies indicate that inconsistencies in target volume delineation may be larger than errors in all other steps of the treatment planning and delivery process. The aim of this paper is to summarize the degree of delineation uncertainties for different tumour sites reported in the literature and review the effect of strategies to minimize them. Conclusions. Our review confirmed that interobserver variability in target volume contouring represents the largest uncertainty in the process for most tumour sites, potentially resulting in a systematic error in dose delivery, which could influence local control in individual patients. For most tumour sites the optimal combination of imaging modalities for target delineation still needs to be determined. Strict use of delineation guidelines and protocols is advisable both in every day clinical practice and in clinical studies to diminish interobserver variability. Continuing medical education of radiation oncologists cannot be overemphasized, intensive formal training on interpretation of sectional imaging should be included in the program for radiation oncology residents.
Ključne besede:target volume, interobserver variability, delineation uncertainties, imaging
Status publikacije:Objavljeno
Verzija publikacije:Objavljena publikacija
Datum objave:01.09.2016
Založnik:Association of Radiology and Oncology
Leto izida:2016
Št. strani:str. 254-262, I
Številčenje:Vol. 50, no. 3
Izvor:Ljubljana
PID:20.500.12556/DiRROS-18868 Novo okno
UDK:615.849
ISSN pri članku:1318-2099
DOI:10.1515/raon-2016-0023 Novo okno
COBISS.SI-ID:2488955 Novo okno
Avtorske pravice:by Authors
Datum objave v DiRROS:30.04.2024
Število ogledov:766
Število prenosov:556
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
  
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del revije

Naslov:Radiology and oncology
Skrajšan naslov:Radiol. oncol.
Založnik:Slovenian Medical Society - Section of Radiology, Croatian Medical Association - Croatian Society of Radiology
ISSN:1318-2099
COBISS.SI-ID:32649472 Novo okno

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:radioterapija, obsevanje, tarčni volumni, vrisovanje, razlike, zmanjševanje neujemanja