Vaš brskalnik ne omogoča JavaScript!
JavaScript je nujen za pravilno delovanje teh spletnih strani. Omogočite JavaScript ali uporabite sodobnejši brskalnik.
Digitalni repozitorij raziskovalnih organizacij Slovenije
Uvodnik
Iskanje
Brskanje
Statistika
Obvestila
Kontakti
Prijava
Izpis gradiva
A+
|
A-
|
|
SLO
|
ENG
Naslov:
Tertiary collimator system for stereotactic radiosurgery with linear accelerator
Avtorji:
ID
Casar, Božidar
(Avtor)
Datoteke:
PDF - Predstavitvena datoteka,
prenos
(1,30 MB)
MD5: F9A7DF7D62E53DA44E5798651638091D
Jezik:
Angleški jezik
Tipologija:
1.01 - Izvirni znanstveni članek
Organizacija:
OI - Onkološki inštitut Ljubljana
Povzetek:
In the last decade, stereotactic radiosurgery (SRS) with linear accelerator (linac) has become an important irradiation technique for a variety of malignant and benign intracranial lesions. Although there exist some other radiosurgery techniques, linac based SRS meets the requirements needed for SRSwith low cost modifications. On of the most important additional parts of the equipment is tertiary collimator system which can be attached onto the linac head. We designed and built such system that can be easily fixed onto linac PHILIPS SL - 75/5 with 5 MV photon energy. In our department, we alreadyuse this linac for conventional radiation therapy. Our tertiary collimator system meets all the requirements important for this special modality of radiation therapy. It allows fine centering of the system and has ten various collimators with divergent circular openings having a nominal field diameter ranging from 1.0 cm to 4.0 cm at the isocenter. The accuracy ofthe system was checked by exposing x - ray films at various gantry positions, and recording misalignment of the beams. The width of penumbra was determined using two different dosimetry techniques (film dosimetry and diode measurements).
Status publikacije:
Objavljeno
Verzija publikacije:
Objavljena publikacija
Datum objave:
01.01.1998
Založnik:
Slovenian Medical Society - Section of Radiology ; Croatian Medical Association - Croatian Society of Radiology
Leto izida:
1998
Št. strani:
str. 125-128
Številčenje:
Let. 32, št. 1
Izvor:
Ljubljana
PID:
20.500.12556/DiRROS-17885
UDK:
617
ISSN pri članku:
1318-2099
COBISS.SI-ID:
7653593
Avtorske pravice:
by Authors
Opomba:
Life sciences '97 and 2nd Slovenian-Croatian meeting on Molecular oncology today; 1997 Oct 16-19; Gozd Martuljek; BSDOCID37118;
Datum objave v DiRROS:
19.01.2024
Število ogledov:
440
Število prenosov:
126
Metapodatki:
Citiraj gradivo
Navadno besedilo
BibTeX
EndNote XML
EndNote/Refer
RIS
ABNT
ACM Ref
AMA
APA
Chicago 17th Author-Date
Harvard
IEEE
ISO 690
MLA
Vancouver
:
Kopiraj citat
Objavi na:
Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.
Gradivo je del revije
Naslov:
Radiology and oncology
Skrajšan naslov:
Radiol. oncol.
Založnik:
Slovenian Medical Society - Section of Radiology, Croatian Medical Association - Croatian Society of Radiology
ISSN:
1318-2099
COBISS.SI-ID:
32649472
Sekundarni jezik
Jezik:
Slovenski jezik
Naslov:
Tarciarni kolimatorski sistem za stereotaktično radiokirurgijo z linearnim pospeševalnikom
Nazaj