Digitalni repozitorij raziskovalnih organizacij Slovenije

Iskanje po repozitoriju
A+ | A- | Pomoč | SLO | ENG

Iskalni niz: išči po
išči po
išči po
išči po

Možnosti:
  Ponastavi


Iskalni niz: "ključne besede" (corrosion) .

31 - 40 / 49
Na začetekNa prejšnjo stran12345Na naslednjo stranNa konec
31.
Effect of the microstructural properties of copper on corrosion performance
Tadeja Kosec, Jure Voglar, Petra Močnik, Andraž Legat, 2021, izvirni znanstveni članek

Povzetek: The aim of the study was to define the influence of microstructural properties on the electrochemical properties of copper in four different forms: copper in sheet form, copper doped with phosphorus, electroplated copper and copper wire. Open circuit potential and polarization resistance measurements were carried out in order to determine the electrochemical properties and corrosion rates of copper in 0.1 M NaCl solution in oxic conditions at ambient temperature. Statistical evaluation of the electrochemical data was performed in order to differentiate between the various forms of copper samples. Microstructural and electrochemical investigations were combined with electron microscopy and Raman analysis of the corrosion products after immersion of the copper samples in a 0.1 M NaCl solution for 30 days. The various morphologies of copper corrosion products were identified and analyzed by Raman spectroscopy for the various forms of copper.
Ključne besede: copper, microstructura, corrosion, Raman
Objavljeno v DiRROS: 19.07.2023; Ogledov: 293; Prenosov: 143
.pdf Celotno besedilo (2,24 MB)
Gradivo ima več datotek! Več...

32.
Sensor development for corrosion monitoring of stainless steels in H2SO4 solutions
Miha Hren, Tadeja Kosec, Mari Lindgren, Elina Huttunen-Saarivirta, Andraž Legat, 2021, izvirni znanstveni članek

Povzetek: Equipment made of different stainless steels is often used in the hydrometallurgical processing industry. In this study, an electrical resistance sensor was developed for monitoring corrosion in acidic solutions at high temperature. Two types of stainless steel were used as the electrode materials, namely grade 316L stainless steel (EN 1.4404) and grade 2507 duplex stainless steel (EN 1.4410). The materials and sensors were exposed to a 10% H2SO4 solution containing 5000 mg/L of NaCl at various temperatures. Results from the sensors were verified using electrochemical techniques and postexposure examination. Results showed that the microstructure played an important role in the interpretation of corrosion rates, highlighting the importance of using an appropriate stainless steel for the production of sensors. Electrochemical tests and postexposure examination both showed that the grade 2507 had a significantly lower corrosion rate compared to the grade 316L. Under industrial‑process conditions, the results for the grade 2507 sensor were promising with respect to sensor durability and performance, despite the extremely harsh operating environment.
Ključne besede: stainless steel, hydrometallurgical industry, sulphuric acid, electrical resistance sensor, corrosion
Objavljeno v DiRROS: 05.07.2023; Ogledov: 318; Prenosov: 181
.pdf Celotno besedilo (5,12 MB)
Gradivo ima več datotek! Več...

33.
Characterizing steel corrosion in different alkali-activated mortars
Nina Gartner, Miha Hren, Tadeja Kosec, Andraž Legat, 2021, izvirni znanstveni članek

Povzetek: Alkali-activated materials (AAMs) present a promising potential alternative to ordinary Portland cement (OPC). The service life of reinforced concrete structures depends greatly on the corrosion resistance of the steel used for reinforcement. Due to the wide range and diverse properties of AAMs, the corrosion processes of steel in these materials is still relatively unknown. Three different alkali-activated mortar mixes, based on fly ash, slag, or metakaolin, were prepared for this research. An ordinary carbon-steel reinforcing bar was installed in each of the mortar mixes. In order to study the corrosion properties of steel in the selected mortars, the specimens were exposed to a saline solution in wet/dry cycles for 17 weeks, and periodic electrochemical impedance spectroscopy (EIS) measurements were performed. The propagation of corrosion damage on the embedded steel bars was followed using X-ray computed microtomography (XCT). Periodic EIS measurements of the AAMs showed different impedance response in individual AAMs. Moreover, these impedance responses also changed over the time of exposure. Interpretation of the results was based on visual and numerical analysis of the corrosion damages obtained by XCT, which confirmed corrosion damage of varying type and extent on steel bars embedded in the tested AAMs.
Ključne besede: corrosion, alkali-activated mortars, steel reinforcement, electrochemical impedance spectroscopy, X-ray computed microtomography, visual analysis
Objavljeno v DiRROS: 05.07.2023; Ogledov: 366; Prenosov: 169
.pdf Celotno besedilo (7,00 MB)
Gradivo ima več datotek! Več...

34.
Corrosion and protection of non-patinated, sulphide- and chloride-patinated bronze
Živa Novak, Tadeja Kosec, 2022, izvirni znanstveni članek

Povzetek: The surface of bronze undergoes changes when it is exposed to a polluted atmosphere, and bronze should therefore be protected from this natural deterioration. The most common protective coating currently in use is Incralac, which includes toxic components and is reported to dissolve a few months after application. This work therefore investigates a fluoropolymer-based coating (FA-MS), and compares it to the protection offered by Incralac. Bronze samples (non-patinated, sulphide-patinated or chloride-patinated) were exposed to simulated urban rain for four months. The corrosion products formed were characterised using SEM/EDS and Raman analyses. To study the protection efficiency of the newly developed fluoropolymer coating (FA-MS) and Incralac protection, various electrochemical methods were used: measurements of open circuit potential linear polarisation and potentiodynamic measurements. Findings show that the FA-MS coating provides a protection efficiency of 71 % for chloride-patinated bronze and 99.5 % for sulphide-patinated bronze. Contact angles of the FA-MS samples were higher than those of the unprotected samples or the samples protected by Incralac, indicating better hydrophobic properties of the FA-MS coating.
Ključne besede: bronze, corrosion, SEM/EDS analyses, Raman spectroscopy, electrochemistry, odprti dostop
Objavljeno v DiRROS: 31.05.2023; Ogledov: 322; Prenosov: 121
.pdf Celotno besedilo (1,30 MB)
Gradivo ima več datotek! Več...

35.
Estimation of the corrosion properties for titanium dental alloys produced by SLM
Tadeja Kosec, Mirjam Bajt Leban, Maja Ovsenik, Matej Kurnik, Igor Kopač, 2022, izvirni znanstveni članek

Povzetek: Titanium alloys are known for their excellent biocompatible properties. The development of additive-manufacturing technologies has increased the interest in the use of Ti-6Al-4V, produced by selective laser melting (SLM) method, also in dentistry, i.e., prosthodontics and orthodontics. In the present paper, the effect of laser printing parameters in the selective laser melting (SLM) process on the porosity and corrosion behavior of Ti-6Al-4V dental alloy was metallographically and electrochemically studied. All the tests were performed in artificial saliva at 37 °C. Different forms of Ti-6Al-4V alloy were selected: a reference sample, i.e., pre-fabricated milling disc in wrought condition and four different 3D-printed samples made from Ti-6Al-4V powder using the SLM method, one being heat treated. Electrochemical, spectroscopic and hardness measurements were employed in the study. It was shown that the SLM-produced Ti-6Al-4V samples with different printing parameters have similar microstructural and electrochemical properties, while the electrochemical properties of a reference and thermally treated 3D-printed sample were different, most probably due to the change in the microstructure of the alloys. The corrosion properties were related to the microstructural properties as well as to the pore density.
Ključne besede: Ti-6Al-4V, dental alloys, artificial saliva, selective laser melting, corrosion
Objavljeno v DiRROS: 31.05.2023; Ogledov: 255; Prenosov: 114
.pdf Celotno besedilo (1,97 MB)
Gradivo ima več datotek! Več...

36.
Comparison of cycling high temperature corrosion at 650°C in the presence of NaCl of various austenitic stainless steels
Mirjam Bajt Leban, Maja Vončina, Tadeja Kosec, Robert Tisu, Matevž Barborič, Jože Medved, 2023, izvirni znanstveni članek

Povzetek: The high temperature corrosion at 650°C in the presence of NaCl at atmospheric pressure of AISI 304L, AISI 309, AISI 310S, AISI 314 and AISI 321 austenitic stainless steel was studied. The specimens were cyclically heated in the furnace and immersed in a 3.5% aqueous NaCl solution after cooling for 15 min. After each cycle, the change in mass of the samples was measured. The corroded samples were analysed by SEM /EDX, and the corrosion products were analysed by XRD. The chloride ions react with the steel surface to form porous and poorly adherent oxides and metal chlorides. After the mass increase during the first exposure cycles, spalling of the oxides occurred. The high temperature austenitic stainless steels (AISI 309, AISI 310S, AISI 314) showed less mass loss than conventional austenitic steels (AISI 304L). Surprisingly, the stainless steel AISI 321 showed a similar low weight loss after the cyclic test as AISI 309, but a detailed analysis of the exposed surfaces after the test showed a similar corrosion attack as for AISI 304. After the cyclic test at high temperature in the presence of NaCl, a higher concentration of Cr and Ni definitely improves the corrosion resistance under the present conditions, but a certain addition of Si is even more obvious.
Ključne besede: austenitic stainless steel, high temperature corrosion, NaCl, exhaust systems, open access
Objavljeno v DiRROS: 31.05.2023; Ogledov: 268; Prenosov: 174
.pdf Celotno besedilo (1,53 MB)
Gradivo ima več datotek! Več...

37.
Corrosion characterization and ion release in SLM-manufactured and wrought Ti6Al4V alloy in an oral environment
Mirjam Bajt Leban, Tadeja Kosec, Matjaž Finšgar, 2022, izvirni znanstveni članek

Povzetek: As-produced and heat-treated TiAlV samples were prepared by selective laser melting and compared to wrought samples of identical chemical composition. Microstructural, corrosion, and spectroscopic studies of additively manufactured samples in artificial saliva at 37 °C, with NaF and at pH 2.3 were as a novelty combined with metal ion release during 42 days immersion. In artificial saliva higher amount of ions was released on SLM specimen when compared to wrought alloy. The total amount of ions released from SLM specimen in AS containing NaF was 10-times higher than in AS, while in AS with lactic acid it was 100-times higher.
Ključne besede: Ti6Al4V, SLM, corrosion, ion release, XPS, ToF-SIMS
Objavljeno v DiRROS: 31.05.2023; Ogledov: 306; Prenosov: 256
.pdf Celotno besedilo (15,86 MB)
Gradivo ima več datotek! Več...

38.
Characterization of steel corrosion processes in various blended cements by means of coupled multi-electrode arrays
Miha Hren, Tadeja Kosec, Andraž Legat, 2023, izvirni znanstveni članek

Povzetek: Supplementary cementitious materials can affect the porosity of concrete, pore solution pH and chloride binding, all of which influence the type and magnitude of corrosion damage. Advanced corrosion monitoring techniques are needed to follow the development of corrosion on steel embedded in concrete across space and over time. In this study, coupled multi-electrode arrays (CMEAs) were used to characterise corrosion processes in OPC and three blended cements. Cyclic wetting with chlorides was undertaken to initiate corrosion. The results showed three distinct types of corrosion: localised corrosion (CEM I), localised corrosion that expanded over time (CEM II), and a combination of localised and general corrosion (CEM III and CEM IV). Cathodic locations were also monitored successfully, and the corrosion behaviour was related to total porosity and pH of the pore solution. MicroCT was used to quantify the volume of corroded material, which agreed well with results calculated from the CMEA measurements.
Ključne besede: blended cements, coupled multi-electrode array, corrosion of steel in concrete, supplementary cementitious materials, open access
Objavljeno v DiRROS: 29.05.2023; Ogledov: 266; Prenosov: 172
.pdf Celotno besedilo (12,61 MB)
Gradivo ima več datotek! Več...

39.
Application of electrochemical methods for studying steel corrosion in alkali-activated materials
Shishir Mundra, Gabriel Samson, Giulia Masi, Rebecca Achenbach, David M. Bastidas, Susana Bernal, Maria Chiara Bignozzi, Maria Criado, Martin Cyr, Nina Gartner, Stefanie von Greve‐Dierfeld, Andraž Legat, Nikoonasab Ali, John L. Provis, Michael Raupach, Gregor J. G. Gluth, 2023, izvirni znanstveni članek

Povzetek: Alkali‐activated materials (AAMs) are binders that can complement and partially substitute the current use of conventional cement. However, the present knowledge about how AAMs protect steel reinforcement in concrete elements is incomplete, and uncertainties exist regarding the application of electrochemical methods to investigate this issue. The present review by EFC WP11‐Task Force ‘Corrosion of steel in alkali‐activated materials’ demonstrates that important differences exist between AAMs and Portland cement, and between different classes of AAMs, which are mainly caused by differing pore solution compositions, and which affect the outcomes of electrochemical measurements. The high sulfide concentrations in blast furnace slag‐based AAMs lead to distinct anodic polarisation curves, unusually low open circuit potentials, and low polarisation resistances, which might be incorrectly interpreted as indicating active corrosion of steel reinforcement. No systematic study of the influence of the steel–concrete interface on the susceptibility of steel to corrosion in AAMs is available. Less common electrochemical methods present an opportunity for future progress in the field.
Ključne besede: alkali-aktivated materials, alkali‐activated materials, anodic/cathodic polarisation, concrete, linear polarisation resistance, open circuit potential, reinforcement corrosion, resistivity
Objavljeno v DiRROS: 29.05.2023; Ogledov: 286; Prenosov: 125
URL Povezava na datoteko
Gradivo ima več datotek! Več...

40.
Differences between 3-D printed and traditionally milled CoCr dental alloy from casted block in oral environment
Mirjam Bajt Leban, Matej Kurnik, Igor Kopač, Matic Klug Jovičević, Bojan Podgornik, Tadeja Kosec, 2023, izvirni znanstveni članek

Povzetek: The aim of this study was to compare corrosion resistance and ion release in CoCr dental alloys with identical chemical compositions produced using different technologies (SLM – selective laser melting and milling from cast blocks) and heat treatment (SLM parts only). The corrosion properties were tested in artificial saliva, artificial saliva with fluoride ions, and artificial saliva with added lactic acid to simulate inflammations. The study included electrochemical tests, microstructural investigation and ion release tests in the three different environments for a total of 42 days. The best performance of CoCr as a result of potentiodynamic polarization was observed in the artificial saliva with added lactic acid, which is in contradiction with the highest ion release measured from all the materials tested and electrochemical impedance spectroscopy that showed a deterioration of the passive layer in an acidic environment. Microstructural investigation revealed that different phases precipitated by heat treatment trigger increased release of Mo and W ions. The printing method does not raise critically ion release from CoCr alloy, while the state of the surface greatly impacts the extent of the ion release. This study demonstrates the importance of an interdisciplinary approach to the study of corrosion and biocompatibility in dental alloys.
Ključne besede: CoCr dental alloy, selective laser melting, corrosion, ion release, artificial saliva
Objavljeno v DiRROS: 29.05.2023; Ogledov: 339; Prenosov: 286
.pdf Celotno besedilo (9,28 MB)
Gradivo ima več datotek! Več...

Iskanje izvedeno v 0.29 sek.
Na vrh